Skip to main content

DCC-3200 Faulty Power Cord Replacement

What you need

  1. DCC-3200 Faulty Power Cord Replacement, Faulty Power Cord: step 1, image 1 of 1
    • First, please be sure that the device is unplugged and that there is no water in the reservoir.

    • Check the power cord for frays or cracks.

  2. DCC-3200 Faulty Power Cord Replacement: step 2, image 1 of 1
    • If the cord appears fine, please flip the device upside-down and unscrew the 4 screws on the bottom.

  3. DCC-3200 Faulty Power Cord Replacement: step 3, image 1 of 1
    • Remove the bottom panel and unclip the power cord from the panel.

  4. DCC-3200 Faulty Power Cord Replacement: step 4, image 1 of 1
    • With the front facing towards you upside down, to the top left of the circular hotplate is a beige circuit board with two screws on either side holding it in. Please unscrew them.

  5. DCC-3200 Faulty Power Cord Replacement: step 5, image 1 of 1
    • Carefully remove the circuit board and unplug the gray ribbon wire that is plugged into it.

  6. DCC-3200 Faulty Power Cord Replacement: step 6, image 1 of 1
    • Check to see if the power cord is connected properly to the circuit board.

  7. DCC-3200 Faulty Power Cord Replacement: step 7, image 1 of 1
    • Strip the wire and twist with the other or solder it back on.

Conclusion

To reassemble your device, follow these instructions in reverse order.