Strikes a arc before I pull trigger

Strikes a arc before I pull trigger

Answer this question I have this problem too

Is this a good question?

Score 0
Add a comment

2 Answers

If your talking about a wire fed welder, it is supposed to do that if the stinger touches the metal before you pull the trigger.

Was this answer helpful?

Score 0
Add a comment

There is not a relay built into the system design to start, or power on, the wire circuit when the trigger is pressed. So the design is more like an Arc welder where the stinger, in this case the wire, circuit is always powered on.

Was this answer helpful?

Score 0