kenmore he5 F25 code

kenmore he5, panel lights work, drum light WILL NOT come on when door open but works with door closed. F25 code, replaced inlet and outlet thermistors, additional code P3E, it just beeps three times when you push start

Answer this question I have this problem too

Is this a good question?

Score 1
4 Comments

Thermal fuse checked out okay

by

My apologies, this is a duplicate post.

by

@barouquebayou

What is the model number of the dryer?

by

Model 110.87088601

by

Add a comment

1 Answer

Most Helpful Answer

Hi @barouquebayou,

Don’t know the answer but according to the tech sheet : “Opening the door while in Diagnostic Test Mode may not activate the drum light. The light will come on when Start is pressed, or upon opening the door after the Diagnostic Test Mode has been cancelled”.

P3E is a code for the door switch opening test when in Diagnostic mode. Closing the door should give a 8:88 code and a beep.

I realize that you replaced the inlet thermister but did you test its connections back to the control board, you didn’t say? (see wiring diagram on p.12 for inlet thermister control board connection points P4/1 and P4/2)

Was this answer helpful?

Score 2

2 Comments:

The drum light will not come on when door is opened, out of diagnostic test mode, will test connections and report back.

by

We replaced the door switch just now and it works.