Skip to main content

Repair information and guides for the iPhone 6 Plus that was released on September 19, 2014. Model: A1522, A1524

1526 Questions View all

touch disease,, -5.7v problem

hi

i have iphone 6 plus with touch problem first i make jumper M1 pin on u2402 because this pin missing then test with diode value and resistant is normal but touch still disease and i measurement PN5V7_SAGE_AVDDN and this voltage only 5.3v im allready change chestnut (u1501) but the problem same -5v7 still low voltage

Answered! View the answer I have this problem too

Is this a good question?

Score 0
Add a comment

1 Answer

Chosen Solution

Have you tried a known good screen?  What is the phones history?

You should not have touched chestnut. Now you have added variables to your repair. I have measured different voltages on that line and yours is acceptable.

You need to diode the connector and find what line is missing. If all the pins measure right I would try another meson than cumulus.

Was this answer helpful?

Score 1

1 Comment:

phone was dropped from a few feet before

i was change lcd and problem still same

and diode value on connector was normal,, and change cumulus and meson (i get from normal board iphone) problem still same

by

Add a comment

Add your answer

Ronald E will be eternally grateful.
View Statistics:

Past 24 Hours: 0

Past 7 Days: 0

Past 30 Days: 6