Skip to main content

The Kenmore Elite HE3 is 7.2 cu. ft. capacity electric dryer by Kenmore.

318 Questions View all

Changed 4-prong to 3-prong after a move.

Kenmore Elite He3 powers on, but will not work. Tested the electricity from outlet and wires (by a retired electrician). He says all work. He advised calling an appliance person to test motherboard, circuits. Each person I telephoned has never heard of a motherboard, circuit board. Please help.

Kismet

Answered! View the answer I have this problem too

Is this a good question?

Score 0
2 Comments

They would just call it a different name, like control board or something similar. This pdf should help with the diagnosis. Kenmore-Elite-HE3-Dryer-Tech-Sheet.pdf

by

@kismet post some images of your outlet, the plug and how it is wired into the machine. Use this guide Adding images to an existing question for that It will allow us to see what you see.

by

Add a comment

1 Answer

Chosen Solution

The 4 prong power cord had the ground (green) wire screwed to the cabinet and the 3 other wires were screwed to the terminal block. A 3 prong power cord doesn’t have a ground (green) wire. The middle terminal on the block has a white (neutral) wire that needs to be screwed to the cabinet where the ground (green) wire was attached. This is a common mistake.

Was this answer helpful?

Score 3