Introduction

Follow this guide in order to fix the cameras in your Oregon Scientific Meep! X2 tablet.

Remove the orange covers from the left and right sides of the device by sliding up against the tabs.
  • Remove the orange covers from the left and right sides of the device by sliding up against the tabs.

Add Comment

You can remove the rear casing by unscrewing all six phillips #00(3.5mm x 4.5mm)screws from the left and right side of the device. You can remove the rear casing by unscrewing all six phillips #00(3.5mm x 4.5mm)screws from the left and right side of the device. You can remove the rear casing by unscrewing all six phillips #00(3.5mm x 4.5mm)screws from the left and right side of the device.
  • You can remove the rear casing by unscrewing all six phillips #00(3.5mm x 4.5mm)screws from the left and right side of the device.

Add Comment

Black Friday
Broken doesn't stand a chance.
Use the plastic opening tools to undo the clips around the edges of the device. Use the plastic opening tools to undo the clips around the edges of the device. Use the plastic opening tools to undo the clips around the edges of the device.
  • Use the plastic opening tools to undo the clips around the edges of the device.

Add Comment

Slip the plastic opening tool under the white, square enclosure of the camera and lift upward to unhook the camera unit from the motherboard. Slip the plastic opening tool under the white, square enclosure of the camera and lift upward to unhook the camera unit from the motherboard.
  • Slip the plastic opening tool under the white, square enclosure of the camera and lift upward to unhook the camera unit from the motherboard.

Add Comment

Pry the second camera out of its slot with one of the plastic opening tools. Be sure to undo the black adhesive foam from the metal casing in order to remove the camera properly.
  • Pry the second camera out of its slot with one of the plastic opening tools.

  • Be sure to undo the black adhesive foam from the metal casing in order to remove the camera properly.

Add Comment

Release the black security clip on the ribbon cable with your plastic opening tool.
  • Release the black security clip on the ribbon cable with your plastic opening tool.

  • Gently disconnect the gold ribbon cable from the motherboard. The two cameras will remain attached to the ribbon cable.

Add Comment

Conclusion

To reassemble your device, follow these instructions in reverse order.

J'mel Henneman

Member since: 01/20/2015

855 Reputation

8 Guides authored

Team

USF Tampa, Team 9-1, Blackwell Winter 2015 Member of USF Tampa, Team 9-1, Blackwell Winter 2015

USFT-BLACKWELL-W15S9G1

3 Members

8 Guides authored

0 Comments

Add Comment

View Statistics:

Past 24 Hours: 0

Past 7 Days: 0

Past 30 Days: 0

All Time: 85