Skip to main content

Milwaukee Hex Impact Driver 2750-20 Output Shaft Bearing Replacement

What you need

  1. Milwaukee Hex Impact Driver 2750-20  Output Shaft Bearing Replacement, Outer Casing: step 1, image 1 of 1
    • Remove the five T9 15.5 mm screws.

    • Remove the single T9 19.5mm screw.

    • Remove the two T9 37mm screws.

  2. Milwaukee Hex Impact Driver 2750-20  Output Shaft Bearing Replacement: step 2, image 1 of 1
    • Remove the drill casing to expose the drill's interior parts.

  3. Milwaukee Hex Impact Driver 2750-20  Output Shaft Bearing Replacement, Output Shaft Bearing: step 3, image 1 of 1
    • Once the interior is open locate the output shaft driver pictured at the left of the screen.

  4. Milwaukee Hex Impact Driver 2750-20  Output Shaft Bearing Replacement: step 4, image 1 of 3 Milwaukee Hex Impact Driver 2750-20  Output Shaft Bearing Replacement: step 4, image 2 of 3 Milwaukee Hex Impact Driver 2750-20  Output Shaft Bearing Replacement: step 4, image 3 of 3
    • Lift the driver head and motor assembly directly out of the outer casing.

    • Pull the driver head away from the motor assembly, separating the two.

  5. Milwaukee Hex Impact Driver 2750-20  Output Shaft Bearing Replacement: step 5, image 1 of 3 Milwaukee Hex Impact Driver 2750-20  Output Shaft Bearing Replacement: step 5, image 2 of 3 Milwaukee Hex Impact Driver 2750-20  Output Shaft Bearing Replacement: step 5, image 3 of 3
    Tool used on this step:
    Tweezers
    $4.99
    Buy
    • Remove the fan and the drive shaft assembly from the motor core assembly.

    • Using a pair of tweezers, remove the retaining ring.

    • Remove the old bearing and reinstall the new retaining clip.

Conclusion

To reassemble your device, follow these instructions in reverse order.