Introduction

This guide will demonstrate how to remove and replace the safety weight in the Holmes HEH8031 Heater.

  1. Ensure the device is unplugged from the wall outlet.
    • Ensure the device is unplugged from the wall outlet.

  2. Remove eight 12-mm Phillips #2 screws from the back cover.
    • Remove eight 12-mm Phillips #2 screws from the back cover.

    • Turn heater over so the controls are facing up.

    • Lift the front housing away from the back of the fan and slowly fold the front housing back down to the floor.

    • Internal wires are connected to both halves of the housing. Be careful when separating the housing.

    • Remove four 12mm Phillips #2 screws from the circuit board.

    • Remove wires from safety weight, as shown.

    • Pull upward on the blue connectors.

      • If connectors are tough to remove, try wiggling while pulling upward.

    • Unscrew the Phillips #2 10 mm screw from the safety weight on the rear housing panel.

Conclusion

To reassemble your device, follow these instructions in reverse order.