Skip to main content

Holmes HEH8031 Safety Weight Replacement

What you need

  1. Holmes HEH8031 Safety Weight Replacement, Housing: step 1, image 1 of 1
    • Ensure the device is unplugged from the wall outlet.

  2. Holmes HEH8031 Safety Weight Replacement: step 2, image 1 of 1
    • Remove eight 12-mm Phillips #2 screws from the back cover.

  3. Holmes HEH8031 Safety Weight Replacement: step 3, image 1 of 2 Holmes HEH8031 Safety Weight Replacement: step 3, image 2 of 2
    • Turn heater over so the controls are facing up.

    • Lift the front housing away from the back of the fan and slowly fold the front housing back down to the floor.

    • Internal wires are connected to both halves of the housing. Be careful when separating the housing.

  4. Holmes HEH8031 Safety Weight Replacement, Circuit Board Removal: step 4, image 1 of 1
    • Remove four 12mm Phillips #2 screws from the circuit board.

  5. Holmes HEH8031 Safety Weight Replacement, Safety Weight: step 5, image 1 of 2 Holmes HEH8031 Safety Weight Replacement, Safety Weight: step 5, image 2 of 2
    • Remove wires from safety weight, as shown.

    • Pull upward on the blue connectors.

    • If connectors are tough to remove, try wiggling while pulling upward.

  6. Holmes HEH8031 Safety Weight Replacement: step 6, image 1 of 1
    • Unscrew the Phillips #2 10 mm screw from the safety weight on the rear housing panel.

Conclusion

To reassemble your device, follow these instructions in reverse order.

Deanna Jack

Member since: 10/12/16

333 Reputation

4 Guides authored

Team

IUPUI, Team 2-1, Baechle Fall 2016 Member of IUPUI, Team 2-1, Baechle Fall 2016

IUPUI-BAECHLE-F16S2G1

4 Members

16 Guides authored

0 Comments

Add Comment

View Statistics:

Past 24 Hours: 1

Past 7 Days: 3

Past 30 Days: 5

All Time: 538