Skip to main content

Handspring Visor Edge Back Panel Replacement

What you need

  1. Handspring Visor Edge Back Panel Replacement, Back Panel: step 1, image 1 of 1
    • Remove the six 4.1 mm Phillips screws from the back plate using the #00 Phillips Scewdriver.

  2. Handspring Visor Edge Back Panel Replacement: step 2, image 1 of 1
    • Remove the gray back plate from the PDA.

  3. Handspring Visor Edge Back Panel Replacement: step 3, image 1 of 2 Handspring Visor Edge Back Panel Replacement: step 3, image 2 of 2
    • Remove the four 2.6 mm Philips screws that are on the sides of the frame.

    • Remove the 3.9 mm Philips screw holding the stylus holster to the frame.

  4. Handspring Visor Edge Back Panel Replacement: step 4, image 1 of 2 Handspring Visor Edge Back Panel Replacement: step 4, image 2 of 2
    • Remove the four 2.6 mm Philips screws on the top and bottom of the frame.

  5. Handspring Visor Edge Back Panel Replacement: step 5, image 1 of 1
    • Gently remove the white frame from the back of the PDA.

Conclusion

To reassemble your device, follow these instructions in reverse order.