Introduction

If you determine that your vacuum is no longer picking up debris, this guide will help you to replace a damaged cyclone to increase the suction.

Parts

No parts required.

Image 1/2: Image 2/2:
  • Press the grey dust cup release button and gently pull the dust cup towards you.

Add Comment

Image 1/1:
  • Twist the large, black portion of the cyclone/dust cup to the right to unlock the black cover and cyclone from the clear dust cup.

Add Comment

Image 1/1:
  • Twist the clear collar to release the wash screen and small circular collar exposing the cyclone attached to the black head.

Add Comment

Image 1/1:
  • Lift the latch on the top of the black cyclone head to open. You can now see the foam filter inside the cyclone portion of the dust cup.

Add Comment

Image 1/1:
  • Remove the white filter by lifting the gray foam filter handle, exposing the screws attaching cyclone to the black head.

Add Comment

Image 1/1:
  • Using a T15 Security Torx Screwdriver, remove the 8 screws.

Add Comment

Image 1/2: Image 2/2:
  • Upon removal of the screws, the cyclone and black head cover will come apart.

Add Comment

Conclusion

To reassemble your device, follow these instructions in reverse order.