{"wikiid":634063,"langid":"en","namespace":"CATEGORY","title":"NextGen 300","revisionid":1430564,"contents_raw":"====== \u200bSave Time, Save Space ======\n\n* ***Flow rates*** from 1 to 300 mL\/min\n* ***Operating pressure*** up to 300 psi (20 bar)\n* Bigger touchscreen, 12 or 15 inches\n* Wider Dynamic Range UV Detector\n* Improved baseline correction supports use of absorbing solvents\n* Faster processing with streamlined user interface\n\n====== Photo Diode Array \u200bDetection\u200b ======\n\n* UV and UV-Vis detectors use PDA technology\n* Display spectra in real time or post-run\n* Collect based on purity indicators\u200b\n\n====== Internal Vapor Sensor ======\n\n* Automatically stop the system if vapors are detected (level is user-configurable) for safe operation\n\n====== Mass Dire\u200bcted Purification ======\n\n* Collect only those peaks matching the mass of your compound\n* Eliminate the need for further analysis\u2014save time in post-purification processing\u200b\n\n====== Integrated ELSD to Collect Non-Ch\u200bromophoric Non\u200b-Volatile Compounds ======\n\n* Integrated into the CombiFlash: No additional system footprint\n* All parameters programmed based on the solvent used or optimize operating conditions for your separation\n* Offers scalability and sensitivity for a wide sample load range\u200b","contents_json":{"type":"doc","content":[{"type":"paragraph","content":[]},{"type":"heading","attrs":{"level":6},"content":[{"type":"text","text":"\u200bSave Time, Save Space"}]},{"type":"bulletList","attrs":[],"content":[{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"Flow rates","marks":[{"type":"bold"}]},{"type":"text","text":" from 1 to 300 mL\/min"}]}]},{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"Operating pressure","marks":[{"type":"bold"}]},{"type":"text","text":" up to 300 psi (20 bar)"}]}]},{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"Bigger touchscreen, 12 or 15 inches"}]}]},{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"Wider Dynamic Range UV Detector"}]}]},{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"Improved baseline correction supports use of absorbing solvents"}]}]},{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"Faster processing with streamlined user interface"}]}]}]},{"type":"heading","attrs":{"level":6},"content":[{"type":"text","text":"Photo Diode Array \u200bDetection\u200b"}]},{"type":"bulletList","attrs":[],"content":[{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"UV and UV-Vis detectors use PDA technology"}]}]},{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"Display spectra in real time or post-run"}]}]},{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"Collect based on purity indicators\u200b"}]}]}]},{"type":"heading","attrs":{"level":6},"content":[{"type":"text","text":"Internal Vapor Sensor"}]},{"type":"bulletList","attrs":[],"content":[{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"Automatically stop the system if vapors are detected (level is user-configurable) for safe operation"}]}]}]},{"type":"heading","attrs":{"level":6},"content":[{"type":"text","text":"Mass Dire\u200bcted Purification"}]},{"type":"bulletList","attrs":[],"content":[{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"Collect only those peaks matching the mass of your compound"}]}]},{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"Eliminate the need for further analysis\u2014save time in post-purification processing\u200b"}]}]}]},{"type":"heading","attrs":{"level":6},"content":[{"type":"text","text":"Integrated ELSD to Collect Non-Ch\u200bromophoric Non\u200b-Volatile Compounds"}]},{"type":"bulletList","attrs":[],"content":[{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"Integrated into the CombiFlash: No additional system footprint"}]}]},{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"All parameters programmed based on the solvent used or optimize operating conditions for your separation"}]}]},{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"Offers scalability and sensitivity for a wide sample load range\u200b"}]}]}]}]},"contents_rendered":"<div class=\"clearer\"><\/div><div class=\"headerContainer\"><a class=\"selfLink\" href=\"#Section__Save_Time_Save_Space\" title=\"Link to this section\" aria-hidden=\"true\" tabindex=\"-1\"><span    class=\"fa-svg-icon\"><svg width=\"16\" height=\"16\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 576 512\" overflow=\"visible\"><!--! Font Awesome Pro 7.3.1 by @fontawesome - https:\/\/fontawesome.com License - https:\/\/fontawesome.com\/license (Commercial License) Copyright 2026 Fonticons, Inc. --><path d=\"M427.5 88c-21.4 0-42.2 6.9-59.3 19.4-11.4-11.7-24.4-22.1-38.4-30.7 27-23.6 61.7-36.7 97.7-36.7 82 0 148.5 66.5 148.5 148.5 0 39.4-15.6 77.1-43.5 105l-79.1 79.1c-27.8 27.8-65.6 43.5-105 43.5-82 0-148.5-66.5-148.5-148.5 0-17.9 3.2-35.5 9.4-51.9 4.6-12.4 18.5-18.7 30.9-14.1S259 220 254.4 232.4c-4.2 11.1-6.4 23-6.4 35.2 0 55.5 45 100.5 100.5 100.5 26.6 0 52.2-10.6 71-29.4l79.1-79.1C517.4 240.6 528 215.1 528 188.5 528 133 483 88 427.5 88zm-200 56c-26.6 0-52.2 10.6-71 29.4L77.4 252.5c-18.8 18.8-29.4 44.4-29.4 71 0 55.5 45 100.5 100.5 100.5 21.4 0 42.2-6.9 59.3-19.4 11.4 11.8 24.4 22.1 38.4 30.7-27 23.6-61.7 36.7-97.7 36.7-82 0-148.5-66.5-148.5-148.5 0-39.4 15.6-77.1 43.5-105l79.1-79.1c27.8-27.8 65.6-43.5 105-43.5 82 0 148.5 66.5 148.5 148.5 0 17.9-3.2 35.5-9.4 51.9-4.6 12.4-18.5 18.7-30.9 14.1S317 292 321.6 279.6c4.2-11.1 6.4-23 6.4-35.1 0-55.5-45-100.5-100.5-100.5z\"\/><\/svg><\/span><\/a><h6 id=\"Section__Save_Time_Save_Space\" class=\"header\">\u200bSave Time, Save Space<\/h6><\/div>\n\n<ul><li><strong>Flow rates<\/strong> from 1 to 300 mL\/min<\/li><li><strong>Operating pressure<\/strong> up to 300 psi (20 bar)<\/li><li>Bigger touchscreen, 12 or 15 inches<\/li><li>Wider Dynamic Range UV Detector<\/li><li>Improved baseline correction supports use of absorbing solvents<\/li><li>Faster processing with streamlined user interface<\/li><\/ul>\n\n<div class=\"clearer\"><\/div><div class=\"headerContainer\"><a class=\"selfLink\" href=\"#Section_Photo_Diode_Array_Detection\" title=\"Link to this section\" aria-hidden=\"true\" tabindex=\"-1\"><span    class=\"fa-svg-icon\"><svg width=\"16\" height=\"16\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 576 512\" overflow=\"visible\"><!--! Font Awesome Pro 7.3.1 by @fontawesome - https:\/\/fontawesome.com License - https:\/\/fontawesome.com\/license (Commercial License) Copyright 2026 Fonticons, Inc. --><path d=\"M427.5 88c-21.4 0-42.2 6.9-59.3 19.4-11.4-11.7-24.4-22.1-38.4-30.7 27-23.6 61.7-36.7 97.7-36.7 82 0 148.5 66.5 148.5 148.5 0 39.4-15.6 77.1-43.5 105l-79.1 79.1c-27.8 27.8-65.6 43.5-105 43.5-82 0-148.5-66.5-148.5-148.5 0-17.9 3.2-35.5 9.4-51.9 4.6-12.4 18.5-18.7 30.9-14.1S259 220 254.4 232.4c-4.2 11.1-6.4 23-6.4 35.2 0 55.5 45 100.5 100.5 100.5 26.6 0 52.2-10.6 71-29.4l79.1-79.1C517.4 240.6 528 215.1 528 188.5 528 133 483 88 427.5 88zm-200 56c-26.6 0-52.2 10.6-71 29.4L77.4 252.5c-18.8 18.8-29.4 44.4-29.4 71 0 55.5 45 100.5 100.5 100.5 21.4 0 42.2-6.9 59.3-19.4 11.4 11.8 24.4 22.1 38.4 30.7-27 23.6-61.7 36.7-97.7 36.7-82 0-148.5-66.5-148.5-148.5 0-39.4 15.6-77.1 43.5-105l79.1-79.1c27.8-27.8 65.6-43.5 105-43.5 82 0 148.5 66.5 148.5 148.5 0 17.9-3.2 35.5-9.4 51.9-4.6 12.4-18.5 18.7-30.9 14.1S317 292 321.6 279.6c4.2-11.1 6.4-23 6.4-35.1 0-55.5-45-100.5-100.5-100.5z\"\/><\/svg><\/span><\/a><h6 id=\"Section_Photo_Diode_Array_Detection\" class=\"header\">Photo Diode Array \u200bDetection\u200b<\/h6><\/div>\n\n<ul><li>UV and UV-Vis detectors use PDA technology<\/li><li>Display spectra in real time or post-run<\/li><li>Collect based on purity indicators\u200b<\/li><\/ul>\n\n<div class=\"clearer\"><\/div><div class=\"headerContainer\"><a class=\"selfLink\" href=\"#Section_Internal_Vapor_Sensor\" title=\"Link to this section\" aria-hidden=\"true\" tabindex=\"-1\"><span    class=\"fa-svg-icon\"><svg width=\"16\" height=\"16\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 576 512\" overflow=\"visible\"><!--! Font Awesome Pro 7.3.1 by @fontawesome - https:\/\/fontawesome.com License - https:\/\/fontawesome.com\/license (Commercial License) Copyright 2026 Fonticons, Inc. --><path d=\"M427.5 88c-21.4 0-42.2 6.9-59.3 19.4-11.4-11.7-24.4-22.1-38.4-30.7 27-23.6 61.7-36.7 97.7-36.7 82 0 148.5 66.5 148.5 148.5 0 39.4-15.6 77.1-43.5 105l-79.1 79.1c-27.8 27.8-65.6 43.5-105 43.5-82 0-148.5-66.5-148.5-148.5 0-17.9 3.2-35.5 9.4-51.9 4.6-12.4 18.5-18.7 30.9-14.1S259 220 254.4 232.4c-4.2 11.1-6.4 23-6.4 35.2 0 55.5 45 100.5 100.5 100.5 26.6 0 52.2-10.6 71-29.4l79.1-79.1C517.4 240.6 528 215.1 528 188.5 528 133 483 88 427.5 88zm-200 56c-26.6 0-52.2 10.6-71 29.4L77.4 252.5c-18.8 18.8-29.4 44.4-29.4 71 0 55.5 45 100.5 100.5 100.5 21.4 0 42.2-6.9 59.3-19.4 11.4 11.8 24.4 22.1 38.4 30.7-27 23.6-61.7 36.7-97.7 36.7-82 0-148.5-66.5-148.5-148.5 0-39.4 15.6-77.1 43.5-105l79.1-79.1c27.8-27.8 65.6-43.5 105-43.5 82 0 148.5 66.5 148.5 148.5 0 17.9-3.2 35.5-9.4 51.9-4.6 12.4-18.5 18.7-30.9 14.1S317 292 321.6 279.6c4.2-11.1 6.4-23 6.4-35.1 0-55.5-45-100.5-100.5-100.5z\"\/><\/svg><\/span><\/a><h6 id=\"Section_Internal_Vapor_Sensor\" class=\"header\">Internal Vapor Sensor<\/h6><\/div>\n\n<ul><li>Automatically stop the system if vapors are detected (level is user-configurable) for safe operation<\/li><\/ul>\n\n<div class=\"clearer\"><\/div><div class=\"headerContainer\"><a class=\"selfLink\" href=\"#Section_Mass_Dire_cted_Purification\" title=\"Link to this section\" aria-hidden=\"true\" tabindex=\"-1\"><span    class=\"fa-svg-icon\"><svg width=\"16\" height=\"16\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 576 512\" overflow=\"visible\"><!--! Font Awesome Pro 7.3.1 by @fontawesome - https:\/\/fontawesome.com License - https:\/\/fontawesome.com\/license (Commercial License) Copyright 2026 Fonticons, Inc. --><path d=\"M427.5 88c-21.4 0-42.2 6.9-59.3 19.4-11.4-11.7-24.4-22.1-38.4-30.7 27-23.6 61.7-36.7 97.7-36.7 82 0 148.5 66.5 148.5 148.5 0 39.4-15.6 77.1-43.5 105l-79.1 79.1c-27.8 27.8-65.6 43.5-105 43.5-82 0-148.5-66.5-148.5-148.5 0-17.9 3.2-35.5 9.4-51.9 4.6-12.4 18.5-18.7 30.9-14.1S259 220 254.4 232.4c-4.2 11.1-6.4 23-6.4 35.2 0 55.5 45 100.5 100.5 100.5 26.6 0 52.2-10.6 71-29.4l79.1-79.1C517.4 240.6 528 215.1 528 188.5 528 133 483 88 427.5 88zm-200 56c-26.6 0-52.2 10.6-71 29.4L77.4 252.5c-18.8 18.8-29.4 44.4-29.4 71 0 55.5 45 100.5 100.5 100.5 21.4 0 42.2-6.9 59.3-19.4 11.4 11.8 24.4 22.1 38.4 30.7-27 23.6-61.7 36.7-97.7 36.7-82 0-148.5-66.5-148.5-148.5 0-39.4 15.6-77.1 43.5-105l79.1-79.1c27.8-27.8 65.6-43.5 105-43.5 82 0 148.5 66.5 148.5 148.5 0 17.9-3.2 35.5-9.4 51.9-4.6 12.4-18.5 18.7-30.9 14.1S317 292 321.6 279.6c4.2-11.1 6.4-23 6.4-35.1 0-55.5-45-100.5-100.5-100.5z\"\/><\/svg><\/span><\/a><h6 id=\"Section_Mass_Dire_cted_Purification\" class=\"header\">Mass Dire\u200bcted Purification<\/h6><\/div>\n\n<ul><li>Collect only those peaks matching the mass of your compound<\/li><li>Eliminate the need for further analysis\u2014save time in post-purification processing\u200b<\/li><\/ul>\n\n<div class=\"clearer\"><\/div><div class=\"headerContainer\"><a class=\"selfLink\" href=\"#Section_Integrated_ELSD_to_Collect_Non_Ch_romophoric_Non_Volatile_Compounds\" title=\"Link to this section\" aria-hidden=\"true\" tabindex=\"-1\"><span    class=\"fa-svg-icon\"><svg width=\"16\" height=\"16\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 576 512\" overflow=\"visible\"><!--! Font Awesome Pro 7.3.1 by @fontawesome - https:\/\/fontawesome.com License - https:\/\/fontawesome.com\/license (Commercial License) Copyright 2026 Fonticons, Inc. --><path d=\"M427.5 88c-21.4 0-42.2 6.9-59.3 19.4-11.4-11.7-24.4-22.1-38.4-30.7 27-23.6 61.7-36.7 97.7-36.7 82 0 148.5 66.5 148.5 148.5 0 39.4-15.6 77.1-43.5 105l-79.1 79.1c-27.8 27.8-65.6 43.5-105 43.5-82 0-148.5-66.5-148.5-148.5 0-17.9 3.2-35.5 9.4-51.9 4.6-12.4 18.5-18.7 30.9-14.1S259 220 254.4 232.4c-4.2 11.1-6.4 23-6.4 35.2 0 55.5 45 100.5 100.5 100.5 26.6 0 52.2-10.6 71-29.4l79.1-79.1C517.4 240.6 528 215.1 528 188.5 528 133 483 88 427.5 88zm-200 56c-26.6 0-52.2 10.6-71 29.4L77.4 252.5c-18.8 18.8-29.4 44.4-29.4 71 0 55.5 45 100.5 100.5 100.5 21.4 0 42.2-6.9 59.3-19.4 11.4 11.8 24.4 22.1 38.4 30.7-27 23.6-61.7 36.7-97.7 36.7-82 0-148.5-66.5-148.5-148.5 0-39.4 15.6-77.1 43.5-105l79.1-79.1c27.8-27.8 65.6-43.5 105-43.5 82 0 148.5 66.5 148.5 148.5 0 17.9-3.2 35.5-9.4 51.9-4.6 12.4-18.5 18.7-30.9 14.1S317 292 321.6 279.6c4.2-11.1 6.4-23 6.4-35.1 0-55.5-45-100.5-100.5-100.5z\"\/><\/svg><\/span><\/a><h6 id=\"Section_Integrated_ELSD_to_Collect_Non_Ch_romophoric_Non_Volatile_Compounds\" class=\"header\">Integrated ELSD to Collect Non-Ch\u200bromophoric Non\u200b-Volatile Compounds<\/h6><\/div>\n\n<ul><li>Integrated into the CombiFlash: No additional system footprint<\/li><li>All parameters programmed based on the solvent used or optimize operating conditions for your separation<\/li><li>Offers scalability and sensitivity for a wide sample load range\u200b<\/li><\/ul>","linked_wikis":[],"can_edit":true,"available_langids":["en","de","es","fr","it","jp","ko","nl","pt","ru","tr","zh"],"ancestors":[{"dataType":"wiki","wikiid":422865,"langid":"en","title":"Chromatography","display_title":"Chromatography","namespace":"CATEGORY","summary":"Support and repair information for devices related to chromatography.","url":"https:\/\/www.ifixit.com\/Device\/Chromatography","text":"Support and repair information for devices related to chromatography.","image":{"id":2110596,"guid":"gpENfgPk3uIfnIa6","mini":"https:\/\/guide-images.cdn.ifixit.com\/igi\/gpENfgPk3uIfnIa6.mini","thumbnail":"https:\/\/guide-images.cdn.ifixit.com\/igi\/gpENfgPk3uIfnIa6.thumbnail","140x105":"https:\/\/guide-images.cdn.ifixit.com\/igi\/gpENfgPk3uIfnIa6.140x105","200x150":"https:\/\/guide-images.cdn.ifixit.com\/igi\/gpENfgPk3uIfnIa6.200x150","standard":"https:\/\/guide-images.cdn.ifixit.com\/igi\/gpENfgPk3uIfnIa6.standard","440x330":"https:\/\/guide-images.cdn.ifixit.com\/igi\/gpENfgPk3uIfnIa6.440x330","medium":"https:\/\/guide-images.cdn.ifixit.com\/igi\/gpENfgPk3uIfnIa6.medium","large":"https:\/\/guide-images.cdn.ifixit.com\/igi\/gpENfgPk3uIfnIa6.large","original":"https:\/\/guide-images.cdn.ifixit.com\/igi\/gpENfgPk3uIfnIa6.full"},"modified_date":1704820159,"author":1},{"dataType":"wiki","wikiid":422861,"langid":"en","title":"Analytical Instruments","display_title":"Analytical Instruments","namespace":"CATEGORY","summary":"Repair and service information pertaining to the analytical instrumentation used in healthcare.","url":"https:\/\/www.ifixit.com\/Device\/Analytical_Instruments","text":"Repair and service information pertaining to the analytical instrumentation used in healthcare.","image":{"id":2110729,"guid":"gsesKAtrqoJY51Qc","mini":"https:\/\/guide-images.cdn.ifixit.com\/igi\/gsesKAtrqoJY51Qc.mini","thumbnail":"https:\/\/guide-images.cdn.ifixit.com\/igi\/gsesKAtrqoJY51Qc.thumbnail","140x105":"https:\/\/guide-images.cdn.ifixit.com\/igi\/gsesKAtrqoJY51Qc.140x105","200x150":"https:\/\/guide-images.cdn.ifixit.com\/igi\/gsesKAtrqoJY51Qc.200x150","standard":"https:\/\/guide-images.cdn.ifixit.com\/igi\/gsesKAtrqoJY51Qc.standard","440x330":"https:\/\/guide-images.cdn.ifixit.com\/igi\/gsesKAtrqoJY51Qc.440x330","medium":"https:\/\/guide-images.cdn.ifixit.com\/igi\/gsesKAtrqoJY51Qc.medium","large":"https:\/\/guide-images.cdn.ifixit.com\/igi\/gsesKAtrqoJY51Qc.large","original":"https:\/\/guide-images.cdn.ifixit.com\/igi\/gsesKAtrqoJY51Qc.full"},"modified_date":1704819414,"author":1},{"dataType":"wiki","wikiid":424439,"langid":"en","title":"Laboratory Equipment","display_title":"Laboratory Equipment","namespace":"CATEGORY","summary":"Service manuals and support documentation for all kinds of medical laboratory equipment, including hospital and research laboratories.","url":"https:\/\/www.ifixit.com\/Device\/Laboratory_Equipment","text":"Service manuals and support documentation for all kinds of medical laboratory equipment, including hospital and research laboratories.","image":{"id":3076845,"guid":"hOQbhKy6EQnGfswf","mini":"https:\/\/guide-images.cdn.ifixit.com\/igi\/hOQbhKy6EQnGfswf.mini","thumbnail":"https:\/\/guide-images.cdn.ifixit.com\/igi\/hOQbhKy6EQnGfswf.thumbnail","140x105":"https:\/\/guide-images.cdn.ifixit.com\/igi\/hOQbhKy6EQnGfswf.140x105","200x150":"https:\/\/guide-images.cdn.ifixit.com\/igi\/hOQbhKy6EQnGfswf.200x150","standard":"https:\/\/guide-images.cdn.ifixit.com\/igi\/hOQbhKy6EQnGfswf.standard","440x330":"https:\/\/guide-images.cdn.ifixit.com\/igi\/hOQbhKy6EQnGfswf.440x330","medium":"https:\/\/guide-images.cdn.ifixit.com\/igi\/hOQbhKy6EQnGfswf.medium","large":"https:\/\/guide-images.cdn.ifixit.com\/igi\/hOQbhKy6EQnGfswf.large","huge":"https:\/\/guide-images.cdn.ifixit.com\/igi\/hOQbhKy6EQnGfswf.huge","original":"https:\/\/guide-images.cdn.ifixit.com\/igi\/hOQbhKy6EQnGfswf.full"},"modified_date":1711402060,"author":668072},{"dataType":"wiki","wikiid":17171,"langid":"en","title":"Medical Device","display_title":"Medical Device","namespace":"CATEGORY","summary":"Repair manuals and support documentation for devices used in a health care setting or procedure.","url":"https:\/\/www.ifixit.com\/Device\/Medical_Device","text":"Repair manuals and support documentation for devices used in a health care setting or procedure.","image":{"id":3076857,"guid":"yy4PBEHTeUqChV3B","mini":"https:\/\/guide-images.cdn.ifixit.com\/igi\/yy4PBEHTeUqChV3B.mini","thumbnail":"https:\/\/guide-images.cdn.ifixit.com\/igi\/yy4PBEHTeUqChV3B.thumbnail","140x105":"https:\/\/guide-images.cdn.ifixit.com\/igi\/yy4PBEHTeUqChV3B.140x105","200x150":"https:\/\/guide-images.cdn.ifixit.com\/igi\/yy4PBEHTeUqChV3B.200x150","standard":"https:\/\/guide-images.cdn.ifixit.com\/igi\/yy4PBEHTeUqChV3B.standard","440x330":"https:\/\/guide-images.cdn.ifixit.com\/igi\/yy4PBEHTeUqChV3B.440x330","medium":"https:\/\/guide-images.cdn.ifixit.com\/igi\/yy4PBEHTeUqChV3B.medium","large":"https:\/\/guide-images.cdn.ifixit.com\/igi\/yy4PBEHTeUqChV3B.large","huge":"https:\/\/guide-images.cdn.ifixit.com\/igi\/yy4PBEHTeUqChV3B.huge","original":"https:\/\/guide-images.cdn.ifixit.com\/igi\/yy4PBEHTeUqChV3B.full"},"modified_date":1792696418,"author":524640},{"dataType":"wiki","wikiid":11000,"langid":"en","title":"Root","display_title":"Root","namespace":"CATEGORY","summary":"","url":"https:\/\/www.ifixit.com\/Device\/Root","text":"Repair guides, manuals, and troubleshooting help for Root. Get everything you need to repair your Root yourself.","image":{"id":243440,"guid":"bhofAWyrmGwRFlak","mini":"https:\/\/guide-images.cdn.ifixit.com\/igi\/bhofAWyrmGwRFlak.mini","thumbnail":"https:\/\/guide-images.cdn.ifixit.com\/igi\/bhofAWyrmGwRFlak.thumbnail","140x105":"https:\/\/guide-images.cdn.ifixit.com\/igi\/bhofAWyrmGwRFlak.140x105","200x150":"https:\/\/guide-images.cdn.ifixit.com\/igi\/bhofAWyrmGwRFlak.200x150","standard":"https:\/\/guide-images.cdn.ifixit.com\/igi\/bhofAWyrmGwRFlak.standard","440x330":"https:\/\/guide-images.cdn.ifixit.com\/igi\/bhofAWyrmGwRFlak.440x330","medium":"https:\/\/guide-images.cdn.ifixit.com\/igi\/bhofAWyrmGwRFlak.medium","large":"https:\/\/guide-images.cdn.ifixit.com\/igi\/bhofAWyrmGwRFlak.large","original":"https:\/\/guide-images.cdn.ifixit.com\/igi\/bhofAWyrmGwRFlak.full"},"modified_date":1705097689,"author":1}],"created_date":1761080404,"modified_date":1768860186,"is_troubleshooting":false,"authors":[{"userid":4938483,"percent":50,"username":"JoshW","avatar_url":"https:\/\/assets.cdn.ifixit.com\/static\/images\/avatars\/User\/ifixit\/avatar-12.thumbnail","profile_url":"https:\/\/www.ifixit.com\/User\/4938483\/JoshW"},{"userid":3945491,"percent":50,"username":"Kris Rodriguez","avatar_url":"https:\/\/guide-images.cdn.ifixit.com\/igi\/TYRsgfOyqHJnJfDt.thumbnail","profile_url":"https:\/\/www.ifixit.com\/User\/3945491\/Kris+Rodriguez"}],"tags":[],"unreviewed_machine_translation":false,"flags":[],"image":{"id":3813685,"guid":"DGVVAQeNDfXvuiFn","mini":"https:\/\/guide-images.cdn.ifixit.com\/igi\/DGVVAQeNDfXvuiFn.mini","thumbnail":"https:\/\/guide-images.cdn.ifixit.com\/igi\/DGVVAQeNDfXvuiFn.thumbnail","140x105":"https:\/\/guide-images.cdn.ifixit.com\/igi\/DGVVAQeNDfXvuiFn.140x105","200x150":"https:\/\/guide-images.cdn.ifixit.com\/igi\/DGVVAQeNDfXvuiFn.200x150","standard":"https:\/\/guide-images.cdn.ifixit.com\/igi\/DGVVAQeNDfXvuiFn.standard","440x330":"https:\/\/guide-images.cdn.ifixit.com\/igi\/DGVVAQeNDfXvuiFn.440x330","medium":"https:\/\/guide-images.cdn.ifixit.com\/igi\/DGVVAQeNDfXvuiFn.medium","large":"https:\/\/guide-images.cdn.ifixit.com\/igi\/DGVVAQeNDfXvuiFn.large","original":"https:\/\/guide-images.cdn.ifixit.com\/igi\/DGVVAQeNDfXvuiFn.full"},"documents":[{"documentid":44221,"guid":"sOxgWN6dWG3mwam3","date":1761080275,"size":4967763,"pages":104,"filename":"CombiFlash-NextGen-User-Manual.pdf","title":"CombiFlash NextGen User Manual","document_extension":"pdf","image":{"id":3813683,"guid":"JMKEqyCYvNPHAAKH","mini":"https:\/\/guide-images.cdn.ifixit.com\/igi\/JMKEqyCYvNPHAAKH.mini","thumbnail":"https:\/\/guide-images.cdn.ifixit.com\/igi\/JMKEqyCYvNPHAAKH.thumbnail","140x105":"https:\/\/guide-images.cdn.ifixit.com\/igi\/JMKEqyCYvNPHAAKH.140x105","200x150":"https:\/\/guide-images.cdn.ifixit.com\/igi\/JMKEqyCYvNPHAAKH.200x150","standard":"https:\/\/guide-images.cdn.ifixit.com\/igi\/JMKEqyCYvNPHAAKH.standard","440x330":"https:\/\/guide-images.cdn.ifixit.com\/igi\/JMKEqyCYvNPHAAKH.440x330","medium":"https:\/\/guide-images.cdn.ifixit.com\/igi\/JMKEqyCYvNPHAAKH.medium","large":"https:\/\/guide-images.cdn.ifixit.com\/igi\/JMKEqyCYvNPHAAKH.large","original":"https:\/\/guide-images.cdn.ifixit.com\/igi\/JMKEqyCYvNPHAAKH.full"},"url":"\/Document\/sOxgWN6dWG3mwam3\/CombiFlash-NextGen-User-Manual.pdf","download_url":"https:\/\/www.ifixit.com\/Document\/Download\/sOxgWN6dWG3mwam3","display":"list"}],"author":4938483,"display_title":"NextGen 300+","page_title":"NextGen 300+ Repair","description":"The CombiFlash\u00ae NextGen 300+ features all available performance and safety options. Flow rate range is from 1 to 300 mL\/min at operating pressures up to 300 psi (20 bar). The system is fitted with a solid load injection valve that can be bypassed if you decide to perform a liquid injection.","children":[],"category_lists":{},"featured_guides":[],"guides":[],"related_wikis":[],"solutions_url":"https:\/\/www.ifixit.com\/Answers\/Device\/NextGen_300","parts":{"url":"https:\/\/www.ifixit.com\/Parts\/NextGen_300","categories":[]},"tools":[],"repairability_score":null,"category_info":[],"source_revisionid":null,"diagrams":[],"info":[{"name":"condition_battery_cycle_count","value":"off","inheritedFrom":"Medical Device"},{"name":"condition_battery_health_percent","value":"off","inheritedFrom":"Medical Device"},{"name":"condition_belt_wear","value":"off","inheritedFrom":"Medical Device"},{"name":"condition_brake_pad_thickness_mm","value":"off","inheritedFrom":"Medical Device"},{"name":"condition_controller_runtime_hours","value":"off","inheritedFrom":"Medical Device"},{"name":"condition_coolant_ph","value":"off","inheritedFrom":"Medical Device"},{"name":"condition_filter_life_percent","value":"off","inheritedFrom":"Medical Device"},{"name":"condition_filter_pressure_drop","value":"off","inheritedFrom":"Medical Device"},{"name":"condition_oil_life","value":"off","inheritedFrom":"Medical Device"},{"name":"condition_oil_life_percent","value":"off","inheritedFrom":"Medical Device"},{"name":"condition_tire_tread_depth_mm","value":"off","inheritedFrom":"Medical Device"},{"name":"condition_water_hardness","value":"off","inheritedFrom":"Medical Device"}],"aliases":[],"maintenance_schedule":{"schedules":[],"notSuggested":[],"inheritedFrom":null,"langid":"en"}}