{"wikiid":414319,"langid":"en","namespace":"CATEGORY","title":"InteliPAP AutoBiLevel Machine with SmartCode","revisionid":1210356,"contents_raw":"The\u00a0***IntelliPAP AutoBiLevel System***\u00a0offers the comfort of AutoAdjust BiLevel therapy and the technology of DeVillbiss' exclusive Flow Rounding to help smooth out breathing patterns between IPAP and EPAP pressures. IntelliPAP units have an internal power supply eliminating the need for a bulky power brick and it is one of the quietest on the market.\n\n***Features***:\n\n* Quiet operation at 26 dBA\n* AutoAdjust - automatic pressure adjustment\n* Adjustable pressure support range\n* Flow Rounding technology\n* Soft Start\n* Auto ON\/OFF function\n* Battery Backup Option\n* SmartCode compliance tracking\n* Automatic altitude adjustment\n* Adjustable pressure ramp\n* Adjustable definition of apnea\/hypopnea\n* Reminder alerts\n* Back lit LCD\n* Easy-to-Follow CPAP user menu\n* 5 Year warranty\n\n[br]\n\n***AutoAdjust***\n\nThe IntelliPAP AutoBiLevel uses the technology of AutoAdjust automatic pressure adjustment combined with bilevel treatment. The maximum IPAP and minimum EPAP levels can be adjusted to meet the needs of the user. The IntelliPAP uses an AutoBiLevel algorithm that allows it to use a lower mean air pressure for a more comfortable therapy.[br]\n[br]\nThe pressure support range (the difference between the IPAP and the EPAP) can be adjusted between zero and 12 cm H2O in increments of .5 cm H2O. The definition of apnea and hypopnea and the delay or ramp setting can be adjusted.\n\n***Flow Rounding Technology and SoftStart***\n\nThe IntelliPAP AutoBiLevel uses Flow Rounding Technology to smooth out the abrupt change between IPAP (inspiration) and EPAP (exhalation) pressures to make the most of the therapy and maximize compliance. The IPAP and EPAP breathing patterns can be adjusted based on a setting of zero for no rounding and up to 5 for a maximum slope or slowest transition from IPAP to EPAP.[br]\n[br]\nSoft Start slowly increases the pressure to the set IPAP pressure over the span of 10 seconds to ease the adjustment to the higher pressures that are frequently required in bilevel therapy.\n\n***Auto On\/Off***\n\nSelect the Auto On\/Off option during set up to have the IntelliPAP AutoBiLevel automatically start the flow of air when you breathe into the mask. The air flow stops when the mask is removed and it no longer senses the breathing.\n\n***Battery Backup Option***\n\nThe IntelliPAP machines use a separate connection for AC and DC power, allowing for the machine to be set up in a battery backup configuration. The included AC power cord can be plugged into an AC power source such as a wall outlet, and the\u00a0''optional''\u00a0++IntelliPAP 12 Volt DC Power Cord++\u00a0can be plugged into a DC power source such as a battery. The IntelliPAP will use the AC power source by default, and if that source should fail, the machine will automatically convert to the DC power source, without any interruption in therapy. If the AC power source becomes available again, the machine will revert back. Please note that if using the heated humidifier, it will not function from DC power.\n\n***SmartCode***\n\nThe IntelliPAP Remote Adherence Monitoring System of SmartCode is an easy way to review sleep data without the cost of buying software. SmartCode messages begin to display on the LCD screen the day after the first treatment. Each is a unique encrypted code containing the results of your sleep therapy. The IntelliPAP confirms compliance using the Adherence Score and doctors use the Adherence Percentage score to determine compliance.[br]\n[br]\nSmartCode Adherence is based on the best thirty days of consecutive usage and the Codes can be generated in the following schedule:\n\n* 1 Day\n* 7 Days\n* 30 Days\n* 90 Days\n* Cumulative\n\n***Modes***\n\nThe IntelliPAP AutoBiLevel may be used in the following modes of operation:\n\n* AutoBiLevel\n* BiLevel\n* CPAP","contents_json":{"type":"doc","content":[{"type":"paragraph","content":[]},{"type":"paragraph","content":[]},{"type":"paragraph","content":[]},{"type":"paragraph","content":[{"type":"text","text":"The\u00a0"},{"type":"text","text":"IntelliPAP AutoBiLevel System","marks":[{"type":"bold"}]},{"type":"text","text":"\u00a0offers the comfort of AutoAdjust BiLevel therapy and the technology of DeVillbiss' exclusive Flow Rounding to help smooth out breathing patterns between IPAP and EPAP pressures. IntelliPAP units have an internal power supply eliminating the need for a bulky power brick and it is one of the quietest on the market."}]},{"type":"paragraph","content":[{"type":"text","text":"Features","marks":[{"type":"bold"}]},{"type":"text","text":":"}]},{"type":"bulletList","attrs":[],"content":[{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"Quiet operation at 26 dBA"}]}]},{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"AutoAdjust - automatic pressure adjustment"}]}]},{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"Adjustable pressure support range"}]}]},{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"Flow Rounding technology"}]}]},{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"Soft Start"}]}]},{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"Auto ON\/OFF function"}]}]},{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"Battery Backup Option"}]}]},{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"SmartCode compliance tracking"}]}]},{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"Automatic altitude adjustment"}]}]},{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"Adjustable pressure ramp"}]}]},{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"Adjustable definition of apnea\/hypopnea"}]}]},{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"Reminder alerts"}]}]},{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"Back lit LCD"}]}]},{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"Easy-to-Follow CPAP user menu"}]}]},{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"5 Year warranty"}]}]}]},{"type":"paragraph","content":[{"type":"customHardBreak"}]},{"type":"paragraph","content":[{"type":"text","text":"AutoAdjust","marks":[{"type":"bold"}]}]},{"type":"paragraph","content":[{"type":"text","text":"The IntelliPAP AutoBiLevel uses the technology of AutoAdjust automatic pressure adjustment combined with bilevel treatment. The maximum IPAP and minimum EPAP levels can be adjusted to meet the needs of the user. The IntelliPAP uses an AutoBiLevel algorithm that allows it to use a lower mean air pressure for a more comfortable therapy."},{"type":"customHardBreak"},{"type":"customHardBreak"},{"type":"text","text":"The pressure support range (the difference between the IPAP and the EPAP) can be adjusted between zero and 12 cm H2O in increments of .5 cm H2O. The definition of apnea and hypopnea and the delay or ramp setting can be adjusted."}]},{"type":"paragraph","content":[{"type":"text","text":"Flow Rounding Technology and SoftStart","marks":[{"type":"bold"}]}]},{"type":"paragraph","content":[{"type":"text","text":"The IntelliPAP AutoBiLevel uses Flow Rounding Technology to smooth out the abrupt change between IPAP (inspiration) and EPAP (exhalation) pressures to make the most of the therapy and maximize compliance. The IPAP and EPAP breathing patterns can be adjusted based on a setting of zero for no rounding and up to 5 for a maximum slope or slowest transition from IPAP to EPAP."},{"type":"customHardBreak"},{"type":"customHardBreak"},{"type":"text","text":"Soft Start slowly increases the pressure to the set IPAP pressure over the span of 10 seconds to ease the adjustment to the higher pressures that are frequently required in bilevel therapy."}]},{"type":"paragraph","content":[{"type":"text","text":"Auto On\/Off","marks":[{"type":"bold"}]}]},{"type":"paragraph","content":[{"type":"text","text":"Select the Auto On\/Off option during set up to have the IntelliPAP AutoBiLevel automatically start the flow of air when you breathe into the mask. The air flow stops when the mask is removed and it no longer senses the breathing."}]},{"type":"paragraph","content":[{"type":"text","text":"Battery Backup Option","marks":[{"type":"bold"}]}]},{"type":"paragraph","content":[{"type":"text","text":"The IntelliPAP machines use a separate connection for AC and DC power, allowing for the machine to be set up in a battery backup configuration. The included AC power cord can be plugged into an AC power source such as a wall outlet, and the\u00a0"},{"type":"text","text":"optional","marks":[{"type":"italic"}]},{"type":"text","text":"\u00a0"},{"type":"text","text":"IntelliPAP 12 Volt DC Power Cord","marks":[{"type":"underline"}]},{"type":"text","text":"\u00a0can be plugged into a DC power source such as a battery. The IntelliPAP will use the AC power source by default, and if that source should fail, the machine will automatically convert to the DC power source, without any interruption in therapy. If the AC power source becomes available again, the machine will revert back. Please note that if using the heated humidifier, it will not function from DC power."}]},{"type":"paragraph","content":[{"type":"text","text":"SmartCode","marks":[{"type":"bold"}]}]},{"type":"paragraph","content":[{"type":"text","text":"The IntelliPAP Remote Adherence Monitoring System of SmartCode is an easy way to review sleep data without the cost of buying software. SmartCode messages begin to display on the LCD screen the day after the first treatment. Each is a unique encrypted code containing the results of your sleep therapy. The IntelliPAP confirms compliance using the Adherence Score and doctors use the Adherence Percentage score to determine compliance."},{"type":"customHardBreak"},{"type":"customHardBreak"},{"type":"text","text":"SmartCode Adherence is based on the best thirty days of consecutive usage and the Codes can be generated in the following schedule:"}]},{"type":"bulletList","attrs":[],"content":[{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"1 Day"}]}]},{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"7 Days"}]}]},{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"30 Days"}]}]},{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"90 Days"}]}]},{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"Cumulative"}]}]}]},{"type":"paragraph","content":[{"type":"text","text":"Modes","marks":[{"type":"bold"}]}]},{"type":"paragraph","content":[{"type":"text","text":"The IntelliPAP AutoBiLevel may be used in the following modes of operation:"}]},{"type":"bulletList","attrs":[],"content":[{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"AutoBiLevel"}]}]},{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"BiLevel"}]}]},{"type":"listItem","content":[{"type":"paragraph","content":[{"type":"text","text":"CPAP"}]}]}]}]},"contents_rendered":"<p>The\u00a0<strong>IntelliPAP AutoBiLevel System<\/strong>\u00a0offers the comfort of AutoAdjust BiLevel therapy and the technology of DeVillbiss' exclusive Flow Rounding to help smooth out breathing patterns between IPAP and EPAP pressures. IntelliPAP units have an internal power supply eliminating the need for a bulky power brick and it is one of the quietest on the market.<\/p>\n\n<p><strong>Features<\/strong>:<\/p>\n\n<ul><li>Quiet operation at 26 dBA<\/li><li>AutoAdjust - automatic pressure adjustment<\/li><li>Adjustable pressure support range<\/li><li>Flow Rounding technology<\/li><li>Soft Start<\/li><li>Auto ON\/OFF function<\/li><li>Battery Backup Option<\/li><li>SmartCode compliance tracking<\/li><li>Automatic altitude adjustment<\/li><li>Adjustable pressure ramp<\/li><li>Adjustable definition of apnea\/hypopnea<\/li><li>Reminder alerts<\/li><li>Back lit LCD<\/li><li>Easy-to-Follow CPAP user menu<\/li><li>5 Year warranty<\/li><\/ul>\n\n<p><br \/><\/p>\n\n<p><strong>AutoAdjust<\/strong><\/p>\n\n<p>The IntelliPAP AutoBiLevel uses the technology of AutoAdjust automatic pressure adjustment combined with bilevel treatment. The maximum IPAP and minimum EPAP levels can be adjusted to meet the needs of the user. The IntelliPAP uses an AutoBiLevel algorithm that allows it to use a lower mean air pressure for a more comfortable therapy.<br \/><br \/>The pressure support range (the difference between the IPAP and the EPAP) can be adjusted between zero and 12 cm H2O in increments of .5 cm H2O. The definition of apnea and hypopnea and the delay or ramp setting can be adjusted.<\/p>\n\n<p><strong>Flow Rounding Technology and SoftStart<\/strong><\/p>\n\n<p>The IntelliPAP AutoBiLevel uses Flow Rounding Technology to smooth out the abrupt change between IPAP (inspiration) and EPAP (exhalation) pressures to make the most of the therapy and maximize compliance. The IPAP and EPAP breathing patterns can be adjusted based on a setting of zero for no rounding and up to 5 for a maximum slope or slowest transition from IPAP to EPAP.<br \/><br \/>Soft Start slowly increases the pressure to the set IPAP pressure over the span of 10 seconds to ease the adjustment to the higher pressures that are frequently required in bilevel therapy.<\/p>\n\n<p><strong>Auto On\/Off<\/strong><\/p>\n\n<p>Select the Auto On\/Off option during set up to have the IntelliPAP AutoBiLevel automatically start the flow of air when you breathe into the mask. The air flow stops when the mask is removed and it no longer senses the breathing.<\/p>\n\n<p><strong>Battery Backup Option<\/strong><\/p>\n\n<p>The IntelliPAP machines use a separate connection for AC and DC power, allowing for the machine to be set up in a battery backup configuration. The included AC power cord can be plugged into an AC power source such as a wall outlet, and the\u00a0<em>optional<\/em>\u00a0<ins>IntelliPAP 12 Volt DC Power Cord<\/ins>\u00a0can be plugged into a DC power source such as a battery. The IntelliPAP will use the AC power source by default, and if that source should fail, the machine will automatically convert to the DC power source, without any interruption in therapy. If the AC power source becomes available again, the machine will revert back. Please note that if using the heated humidifier, it will not function from DC power.<\/p>\n\n<p><strong>SmartCode<\/strong><\/p>\n\n<p>The IntelliPAP Remote Adherence Monitoring System of SmartCode is an easy way to review sleep data without the cost of buying software. SmartCode messages begin to display on the LCD screen the day after the first treatment. Each is a unique encrypted code containing the results of your sleep therapy. The IntelliPAP confirms compliance using the Adherence Score and doctors use the Adherence Percentage score to determine compliance.<br \/><br \/>SmartCode Adherence is based on the best thirty days of consecutive usage and the Codes can be generated in the following schedule:<\/p>\n\n<ul><li>1 Day<\/li><li>7 Days<\/li><li>30 Days<\/li><li>90 Days<\/li><li>Cumulative<\/li><\/ul>\n\n<p><strong>Modes<\/strong><\/p>\n\n<p>The IntelliPAP AutoBiLevel may be used in the following modes of operation:<\/p>\n\n<ul><li>AutoBiLevel<\/li><li>BiLevel<\/li><li>CPAP<\/li><\/ul>","linked_wikis":[],"can_edit":true,"available_langids":["en","de","es","fr","it","jp","ko","nl","pt","ru","tr","zh"],"ancestors":[{"dataType":"wiki","wikiid":414413,"langid":"en","title":"Devilbiss Ventilator","display_title":"DeVilbiss Ventilator","namespace":"CATEGORY","summary":"Repair guides and service information for DeVilbiss \nventilators.","url":"https:\/\/www.ifixit.com\/Device\/Devilbiss_Ventilator","text":"Repair guides and service information for DeVilbiss \nventilators.","image":{"id":2083125,"guid":"TihOZ3dWboYgSr1j","mini":"https:\/\/guide-images.cdn.ifixit.com\/igi\/TihOZ3dWboYgSr1j.mini","thumbnail":"https:\/\/guide-images.cdn.ifixit.com\/igi\/TihOZ3dWboYgSr1j.thumbnail","140x105":"https:\/\/guide-images.cdn.ifixit.com\/igi\/TihOZ3dWboYgSr1j.140x105","200x150":"https:\/\/guide-images.cdn.ifixit.com\/igi\/TihOZ3dWboYgSr1j.200x150","standard":"https:\/\/guide-images.cdn.ifixit.com\/igi\/TihOZ3dWboYgSr1j.standard","440x330":"https:\/\/guide-images.cdn.ifixit.com\/igi\/TihOZ3dWboYgSr1j.440x330","medium":"https:\/\/guide-images.cdn.ifixit.com\/igi\/TihOZ3dWboYgSr1j.medium","large":"https:\/\/guide-images.cdn.ifixit.com\/igi\/TihOZ3dWboYgSr1j.large","original":"https:\/\/guide-images.cdn.ifixit.com\/igi\/TihOZ3dWboYgSr1j.full"},"modified_date":1711400433,"author":2315556},{"dataType":"wiki","wikiid":414149,"langid":"en","title":"Ventilator","display_title":"Ventilator","namespace":"CATEGORY","summary":"Service and repair information for all makes and models of mechanical ventilation (assisted breathing) devices, including ICU, transport, neonatal, and PAP ventilators.","url":"https:\/\/www.ifixit.com\/Device\/Ventilator","text":"Service and repair information for all makes and models of mechanical ventilation (assisted breathing) devices, including ICU, transport, neonatal, and PAP ventilators.","image":{"id":3083122,"guid":"EnjtlsLZvrCsgvKZ","mini":"https:\/\/guide-images.cdn.ifixit.com\/igi\/EnjtlsLZvrCsgvKZ.mini","thumbnail":"https:\/\/guide-images.cdn.ifixit.com\/igi\/EnjtlsLZvrCsgvKZ.thumbnail","140x105":"https:\/\/guide-images.cdn.ifixit.com\/igi\/EnjtlsLZvrCsgvKZ.140x105","200x150":"https:\/\/guide-images.cdn.ifixit.com\/igi\/EnjtlsLZvrCsgvKZ.200x150","standard":"https:\/\/guide-images.cdn.ifixit.com\/igi\/EnjtlsLZvrCsgvKZ.standard","440x330":"https:\/\/guide-images.cdn.ifixit.com\/igi\/EnjtlsLZvrCsgvKZ.440x330","medium":"https:\/\/guide-images.cdn.ifixit.com\/igi\/EnjtlsLZvrCsgvKZ.medium","large":"https:\/\/guide-images.cdn.ifixit.com\/igi\/EnjtlsLZvrCsgvKZ.large","huge":"https:\/\/guide-images.cdn.ifixit.com\/igi\/EnjtlsLZvrCsgvKZ.huge","original":"https:\/\/guide-images.cdn.ifixit.com\/igi\/EnjtlsLZvrCsgvKZ.full"},"modified_date":1746025304,"author":668072},{"dataType":"wiki","wikiid":628736,"langid":"en","title":"Respiratory therapy","display_title":"Respiratory therapy","namespace":"CATEGORY","summary":"This folder contains technical information and documentation related to key devices used in respiratory therapy, essential for supporting and managing patients with respiratory conditions or ventilatory compromise. These devices are critical in hospital settings, outpatient clinics, and home care environments, and are typically operated by respiratory therapists, clinicians, and trained healthcare personnel.","url":"https:\/\/www.ifixit.com\/Device\/Respiratory_therapy","text":"This folder contains technical information and documentation related to key devices used in respiratory therapy, essential for supporting and managing patients with respiratory conditions or ventilatory compromise. These devices are critical in hospital settings, outpatient clinics, and home care environments, and are typically operated by respiratory therapists, clinicians, and trained healthcare personnel.","image":{"id":3638456,"guid":"LHyNeUDGJqEARZ14","mini":"https:\/\/guide-images.cdn.ifixit.com\/igi\/LHyNeUDGJqEARZ14.mini","thumbnail":"https:\/\/guide-images.cdn.ifixit.com\/igi\/LHyNeUDGJqEARZ14.thumbnail","140x105":"https:\/\/guide-images.cdn.ifixit.com\/igi\/LHyNeUDGJqEARZ14.140x105","200x150":"https:\/\/guide-images.cdn.ifixit.com\/igi\/LHyNeUDGJqEARZ14.200x150","standard":"https:\/\/guide-images.cdn.ifixit.com\/igi\/LHyNeUDGJqEARZ14.standard","440x330":"https:\/\/guide-images.cdn.ifixit.com\/igi\/LHyNeUDGJqEARZ14.440x330","medium":"https:\/\/guide-images.cdn.ifixit.com\/igi\/LHyNeUDGJqEARZ14.medium","large":"https:\/\/guide-images.cdn.ifixit.com\/igi\/LHyNeUDGJqEARZ14.large","original":"https:\/\/guide-images.cdn.ifixit.com\/igi\/LHyNeUDGJqEARZ14.full"},"modified_date":1792696876,"author":4626300},{"dataType":"wiki","wikiid":424438,"langid":"en","title":"Clinical Equipment","display_title":"Clinical Equipment","namespace":"CATEGORY","summary":"Service and repair information for medical devices most commonly used in a clinical setting.","url":"https:\/\/www.ifixit.com\/Device\/Clinical_Equipment","text":"Service and repair information for medical devices most commonly used in a clinical setting.","image":{"id":3076694,"guid":"q5qPhLJwOZejRdGi","mini":"https:\/\/guide-images.cdn.ifixit.com\/igi\/q5qPhLJwOZejRdGi.mini","thumbnail":"https:\/\/guide-images.cdn.ifixit.com\/igi\/q5qPhLJwOZejRdGi.thumbnail","140x105":"https:\/\/guide-images.cdn.ifixit.com\/igi\/q5qPhLJwOZejRdGi.140x105","200x150":"https:\/\/guide-images.cdn.ifixit.com\/igi\/q5qPhLJwOZejRdGi.200x150","standard":"https:\/\/guide-images.cdn.ifixit.com\/igi\/q5qPhLJwOZejRdGi.standard","440x330":"https:\/\/guide-images.cdn.ifixit.com\/igi\/q5qPhLJwOZejRdGi.440x330","medium":"https:\/\/guide-images.cdn.ifixit.com\/igi\/q5qPhLJwOZejRdGi.medium","large":"https:\/\/guide-images.cdn.ifixit.com\/igi\/q5qPhLJwOZejRdGi.large","huge":"https:\/\/guide-images.cdn.ifixit.com\/igi\/q5qPhLJwOZejRdGi.huge","original":"https:\/\/guide-images.cdn.ifixit.com\/igi\/q5qPhLJwOZejRdGi.full"},"modified_date":1792696444,"author":668072},{"dataType":"wiki","wikiid":17171,"langid":"en","title":"Medical Device","display_title":"Medical Device","namespace":"CATEGORY","summary":"Repair manuals and support documentation for devices used in a health care setting or procedure.","url":"https:\/\/www.ifixit.com\/Device\/Medical_Device","text":"Repair manuals and support documentation for devices used in a health care setting or procedure.","image":{"id":3076857,"guid":"yy4PBEHTeUqChV3B","mini":"https:\/\/guide-images.cdn.ifixit.com\/igi\/yy4PBEHTeUqChV3B.mini","thumbnail":"https:\/\/guide-images.cdn.ifixit.com\/igi\/yy4PBEHTeUqChV3B.thumbnail","140x105":"https:\/\/guide-images.cdn.ifixit.com\/igi\/yy4PBEHTeUqChV3B.140x105","200x150":"https:\/\/guide-images.cdn.ifixit.com\/igi\/yy4PBEHTeUqChV3B.200x150","standard":"https:\/\/guide-images.cdn.ifixit.com\/igi\/yy4PBEHTeUqChV3B.standard","440x330":"https:\/\/guide-images.cdn.ifixit.com\/igi\/yy4PBEHTeUqChV3B.440x330","medium":"https:\/\/guide-images.cdn.ifixit.com\/igi\/yy4PBEHTeUqChV3B.medium","large":"https:\/\/guide-images.cdn.ifixit.com\/igi\/yy4PBEHTeUqChV3B.large","huge":"https:\/\/guide-images.cdn.ifixit.com\/igi\/yy4PBEHTeUqChV3B.huge","original":"https:\/\/guide-images.cdn.ifixit.com\/igi\/yy4PBEHTeUqChV3B.full"},"modified_date":1792696418,"author":524640},{"dataType":"wiki","wikiid":11000,"langid":"en","title":"Root","display_title":"Root","namespace":"CATEGORY","summary":"","url":"https:\/\/www.ifixit.com\/Device\/Root","text":"Repair guides, manuals, and troubleshooting help for Root. Get everything you need to repair your Root yourself.","image":{"id":243440,"guid":"bhofAWyrmGwRFlak","mini":"https:\/\/guide-images.cdn.ifixit.com\/igi\/bhofAWyrmGwRFlak.mini","thumbnail":"https:\/\/guide-images.cdn.ifixit.com\/igi\/bhofAWyrmGwRFlak.thumbnail","140x105":"https:\/\/guide-images.cdn.ifixit.com\/igi\/bhofAWyrmGwRFlak.140x105","200x150":"https:\/\/guide-images.cdn.ifixit.com\/igi\/bhofAWyrmGwRFlak.200x150","standard":"https:\/\/guide-images.cdn.ifixit.com\/igi\/bhofAWyrmGwRFlak.standard","440x330":"https:\/\/guide-images.cdn.ifixit.com\/igi\/bhofAWyrmGwRFlak.440x330","medium":"https:\/\/guide-images.cdn.ifixit.com\/igi\/bhofAWyrmGwRFlak.medium","large":"https:\/\/guide-images.cdn.ifixit.com\/igi\/bhofAWyrmGwRFlak.large","original":"https:\/\/guide-images.cdn.ifixit.com\/igi\/bhofAWyrmGwRFlak.full"},"modified_date":1705097689,"author":1}],"created_date":1584980415,"modified_date":1711400427,"is_troubleshooting":false,"authors":[{"userid":2594434,"percent":42.86,"username":"[deleted]","avatar_url":"https:\/\/assets.cdn.ifixit.com\/static\/images\/avatars\/User\/ifixit\/avatar-8.thumbnail","profile_url":"https:\/\/www.ifixit.com\/User\/2594434\/%5Bdeleted%5D"},{"userid":1,"percent":28.57,"username":"iRobot","avatar_url":"https:\/\/guide-images.cdn.ifixit.com\/igi\/AjiayMD6LWqf5FAL.thumbnail","profile_url":"https:\/\/www.ifixit.com\/User\/1\/iRobot"},{"userid":1020837,"percent":14.29,"username":"Kristen Gismondi","avatar_url":"https:\/\/guide-images.cdn.ifixit.com\/igi\/BCARRlVWyqbrI13Z.thumbnail","profile_url":"https:\/\/www.ifixit.com\/User\/1020837\/Kristen+Gismondi"},{"userid":1162242,"percent":14.29,"username":"Adam O'Camb","avatar_url":"https:\/\/guide-images.cdn.ifixit.com\/igi\/KCToEniXHcINvUmY.thumbnail","profile_url":"https:\/\/www.ifixit.com\/User\/1162242\/Adam+O%27Camb"}],"tags":["BiPAP","CPAP","ventilator"],"unreviewed_machine_translation":false,"flags":[],"image":{"id":2044813,"guid":"6ilolpyZkXF2puio","mini":"https:\/\/guide-images.cdn.ifixit.com\/igi\/6ilolpyZkXF2puio.mini","thumbnail":"https:\/\/guide-images.cdn.ifixit.com\/igi\/6ilolpyZkXF2puio.thumbnail","140x105":"https:\/\/guide-images.cdn.ifixit.com\/igi\/6ilolpyZkXF2puio.140x105","200x150":"https:\/\/guide-images.cdn.ifixit.com\/igi\/6ilolpyZkXF2puio.200x150","standard":"https:\/\/guide-images.cdn.ifixit.com\/igi\/6ilolpyZkXF2puio.standard","440x330":"https:\/\/guide-images.cdn.ifixit.com\/igi\/6ilolpyZkXF2puio.440x330","medium":"https:\/\/guide-images.cdn.ifixit.com\/igi\/6ilolpyZkXF2puio.medium","large":"https:\/\/guide-images.cdn.ifixit.com\/igi\/6ilolpyZkXF2puio.large","huge":"https:\/\/guide-images.cdn.ifixit.com\/igi\/6ilolpyZkXF2puio.huge","original":"https:\/\/guide-images.cdn.ifixit.com\/igi\/6ilolpyZkXF2puio.full"},"documents":[{"documentid":6817,"guid":"3K5EwSidcHTNyxNf","date":1584980379,"size":198039,"pages":2,"filename":"IntelliPAP-Std-Quick-Start-Gui.pdf","title":"Quick Start Guide","document_extension":"pdf","image":{"id":2044805,"guid":"e3OeRmvpsTL3wSB4","mini":"https:\/\/guide-images.cdn.ifixit.com\/igi\/e3OeRmvpsTL3wSB4.mini","thumbnail":"https:\/\/guide-images.cdn.ifixit.com\/igi\/e3OeRmvpsTL3wSB4.thumbnail","140x105":"https:\/\/guide-images.cdn.ifixit.com\/igi\/e3OeRmvpsTL3wSB4.140x105","200x150":"https:\/\/guide-images.cdn.ifixit.com\/igi\/e3OeRmvpsTL3wSB4.200x150","standard":"https:\/\/guide-images.cdn.ifixit.com\/igi\/e3OeRmvpsTL3wSB4.standard","440x330":"https:\/\/guide-images.cdn.ifixit.com\/igi\/e3OeRmvpsTL3wSB4.440x330","medium":"https:\/\/guide-images.cdn.ifixit.com\/igi\/e3OeRmvpsTL3wSB4.medium","large":"https:\/\/guide-images.cdn.ifixit.com\/igi\/e3OeRmvpsTL3wSB4.large","original":"https:\/\/guide-images.cdn.ifixit.com\/igi\/e3OeRmvpsTL3wSB4.full"},"url":"\/Document\/3K5EwSidcHTNyxNf\/IntelliPAP-Std-Quick-Start-Gui.pdf","download_url":"https:\/\/www.ifixit.com\/Document\/Download\/3K5EwSidcHTNyxNf","display":"list"},{"documentid":6818,"guid":"OkhPxvFHVJTjGN1H","date":1584980404,"size":1939188,"pages":68,"filename":"A-DV57_Rev_E-FINAL.pdf","title":"Manual","document_extension":"pdf","image":{"id":2044806,"guid":"lKjYAXXGGxYtPQga","mini":"https:\/\/guide-images.cdn.ifixit.com\/igi\/lKjYAXXGGxYtPQga.mini","thumbnail":"https:\/\/guide-images.cdn.ifixit.com\/igi\/lKjYAXXGGxYtPQga.thumbnail","140x105":"https:\/\/guide-images.cdn.ifixit.com\/igi\/lKjYAXXGGxYtPQga.140x105","200x150":"https:\/\/guide-images.cdn.ifixit.com\/igi\/lKjYAXXGGxYtPQga.200x150","standard":"https:\/\/guide-images.cdn.ifixit.com\/igi\/lKjYAXXGGxYtPQga.standard","440x330":"https:\/\/guide-images.cdn.ifixit.com\/igi\/lKjYAXXGGxYtPQga.440x330","medium":"https:\/\/guide-images.cdn.ifixit.com\/igi\/lKjYAXXGGxYtPQga.medium","large":"https:\/\/guide-images.cdn.ifixit.com\/igi\/lKjYAXXGGxYtPQga.large","original":"https:\/\/guide-images.cdn.ifixit.com\/igi\/lKjYAXXGGxYtPQga.full"},"url":"\/Document\/OkhPxvFHVJTjGN1H\/A-DV57_Rev_E-FINAL.pdf","download_url":"https:\/\/www.ifixit.com\/Document\/Download\/OkhPxvFHVJTjGN1H","display":"list"},{"documentid":6820,"guid":"gBvCWVqd5AkVOtKl","date":1584980567,"size":408878,"pages":1,"filename":"LT-2158-REV-A_IntelliPAP_Spec_.pdf","title":"Specifications","document_extension":"pdf","image":{"id":2044811,"guid":"YuH4fCSDeqRLlsYm","mini":"https:\/\/guide-images.cdn.ifixit.com\/igi\/YuH4fCSDeqRLlsYm.mini","thumbnail":"https:\/\/guide-images.cdn.ifixit.com\/igi\/YuH4fCSDeqRLlsYm.thumbnail","140x105":"https:\/\/guide-images.cdn.ifixit.com\/igi\/YuH4fCSDeqRLlsYm.140x105","200x150":"https:\/\/guide-images.cdn.ifixit.com\/igi\/YuH4fCSDeqRLlsYm.200x150","standard":"https:\/\/guide-images.cdn.ifixit.com\/igi\/YuH4fCSDeqRLlsYm.standard","440x330":"https:\/\/guide-images.cdn.ifixit.com\/igi\/YuH4fCSDeqRLlsYm.440x330","medium":"https:\/\/guide-images.cdn.ifixit.com\/igi\/YuH4fCSDeqRLlsYm.medium","large":"https:\/\/guide-images.cdn.ifixit.com\/igi\/YuH4fCSDeqRLlsYm.large","original":"https:\/\/guide-images.cdn.ifixit.com\/igi\/YuH4fCSDeqRLlsYm.full"},"url":"\/Document\/gBvCWVqd5AkVOtKl\/LT-2158-REV-A_IntelliPAP_Spec_.pdf","download_url":"https:\/\/www.ifixit.com\/Document\/Download\/gBvCWVqd5AkVOtKl","display":"list"}],"author":2594434,"display_title":"InteliPAP AutoBiLevel Machine with SmartCode","page_title":"InteliPAP AutoBiLevel Machine with SmartCode Repair","description":"Repair guides and service information for the InteliPAP AutoBiLevel Machine.","children":[],"category_lists":{},"featured_guides":[],"guides":[],"related_wikis":[],"solutions_url":"https:\/\/www.ifixit.com\/Answers\/Device\/InteliPAP_AutoBiLevel_Machine_with_SmartCode","parts":{"url":"https:\/\/www.ifixit.com\/Parts\/InteliPAP_AutoBiLevel_Machine_with_SmartCode","categories":[]},"tools":[],"repairability_score":null,"category_info":[],"source_revisionid":null,"diagrams":[],"info":[{"name":"condition_belt_wear","value":"off","inheritedFrom":"Medical Device"},{"name":"condition_brake_pad_thickness_mm","value":"off","inheritedFrom":"Medical Device"},{"name":"condition_controller_runtime_hours","value":"off","inheritedFrom":"Medical Device"},{"name":"condition_coolant_ph","value":"off","inheritedFrom":"Medical Device"},{"name":"condition_filter_pressure_drop","value":"off","inheritedFrom":"Medical Device"},{"name":"condition_oil_life","value":"off","inheritedFrom":"Medical Device"},{"name":"condition_oil_life_percent","value":"off","inheritedFrom":"Medical Device"},{"name":"condition_tire_tread_depth_mm","value":"off","inheritedFrom":"Medical Device"},{"name":"condition_water_hardness","value":"off","inheritedFrom":"Medical Device"},{"name":"condition_battery_cycle_count","value":"on","inheritedFrom":"Clinical Equipment"},{"name":"condition_battery_health_percent","value":"on","inheritedFrom":"Clinical Equipment"},{"name":"condition_filter_life_percent","value":"on","inheritedFrom":"Respiratory therapy"}],"aliases":[],"maintenance_schedule":{"schedules":[],"notSuggested":[],"inheritedFrom":null,"langid":"en"}}