Introduction

If your device is not working due to a problem with your power cord this guide will allow you to replace it to fix your problem.

Unscrew the 12 mm Phillips head screws located at the top of the cover and at the bottom two corners, using a Phillips #1 Screwdriver. Unscrew the 12 mm Phillips head screws located at the top of the cover and at the bottom two corners, using a Phillips #1 Screwdriver.
  • Unscrew the 12 mm Phillips head screws located at the top of the cover and at the bottom two corners, using a Phillips #1 Screwdriver.

Add Comment

Remove the cover from the device. Remove the cover from the device. Remove the cover from the device.
  • Remove the cover from the device.

Add Comment

Unscrew the black 5.556 mm Phillip head screw on the power switch, closest to the power cord with a Phillips #0 Screwdriver. Unscrew the black 5.556 mm Phillip head screw on the power switch, closest to the power cord with a Phillips #0 Screwdriver. Unscrew the black 5.556 mm Phillip head screw on the power switch, closest to the power cord with a Phillips #0 Screwdriver.
  • Unscrew the black 5.556 mm Phillip head screw on the power switch, closest to the power cord with a Phillips #0 Screwdriver.

Add Comment

Gently remove the black wire connected to the black screw. Gently remove the black wire connected to the black screw.
  • Gently remove the black wire connected to the black screw.

Add Comment

Remove the white wire connected to the power cord and the motor by grabbing the white wire firmly on both sides near the motor mounting and wiggling until release. Remove the white wire connected to the power cord and the motor by grabbing the white wire firmly on both sides near the motor mounting and wiggling until release. Remove the white wire connected to the power cord and the motor by grabbing the white wire firmly on both sides near the motor mounting and wiggling until release.
  • Remove the white wire connected to the power cord and the motor by grabbing the white wire firmly on both sides near the motor mounting and wiggling until release.

Add Comment

Remove the power cord from its mount at the bottom of the device. Remove the power cord from its mount at the bottom of the device.
  • Remove the power cord from its mount at the bottom of the device.

Add Comment

Conclusion

To reassemble your device, follow these instructions in reverse order.

Sophia Swearengin

Member since: 09/26/2017

501 Reputation

5 Guides authored

Team

USF Tampa, Team S14-G5, Boczar Fall 2017 Member of USF Tampa, Team S14-G5, Boczar Fall 2017

USFT-BOCZAR-F17S14G5

2 Members

5 Guides authored

0 Comments

Add Comment

View Statistics:

Past 24 Hours: 0

Past 7 Days: 0

Past 30 Days: 2

All Time: 47