Introduction
The HTC Vive's sensor array may not track your movements even when the rest of the device appears to be functional. This guide will show you how to replace the Vive's sensor array assembly.
Tools
Parts
No parts required.
-
-
Slide the HTC panel covering the cables forward, away from the Vive.
-
Gently pull on each of the four connectors to remove the sound and Three-in-One cables.
-
-
-
Pull the facerest cushion off away from the Vive, separating the hook and loop tape.
-
-
-
Orient the Vive so that the camera is facing towards you and the connector ports are facing upwards, as in the photos.
-
Use a plastic opening tool to gently pry up the left side of the outer sheath.
-
If the left sheath is glued down, slide your plastic opening tool along the middle seam to break the bond.
-
Slide the left side of the sheath outwards.
-
-
-
Remove the five 4mm Philips #00 screws holding the sensor array to the motherboard.
-
Remove the two 4mm Philips #00 screws holding the sensor array to the midframe.
-
-
-
Lift the sensor array away from the rest of the Vive until the camera cable tugs back and hold it in place.
-
Disconnect the camera by lifting its ribbon cable up and away from the motherboard using a pair of ESD safe tweezers.
-
Lift the sensor array upwards away from the motherboard to separate the array from the device fully.
-
To reassemble your device, follow these instructions in reverse order.
To reassemble your device, follow these instructions in reverse order.
Cancel: I did not complete this guide.
One other person completed this guide.