This guide will show the user how to remove the outer casing of the Bionaire BAP 600.

Tools

No tools required.

Parts

No parts required.

Image 1/1:
  • Rotate base counterclockwise, supporting top with opposite hand.

Add Comment

Image 1/1:
  • Pull base away from housing exposing air filter.

Add Comment

Image 1/1:
  • Grab the edge of the filter housing and pull the filter away from the rest of the device.

Add Comment

Image 1/1:
  • Gently pull apart each fold of the filter to check for abrasions or other anomalies. Clean with a dust rag if necessary.

Add Comment

Image 1/1:
  • Remove all 6 screws from the LED housing.

Add Comment

Image 1/1:
  • After the 6 screws are removed, remove the LED housing from the bottom of the device by lifting it off.

Add Comment

Image 1/1:
  • Using two fingers lift the translucent LED cover from the inside. Repeat this step for the second tab.

Add Comment

Image 1/1:
  • After lifting 45 degrees, pull the translucent tab away from thee housing. Repeat this step for the second LED cover.

Add Comment

Image 1/1:
  • Locate the tab about 1 inch below the top vent. Insert a flat tool laterally past the tab and press in toward the center of the device. As the tab is being held down, pull the two halves of the egg apart to keep the shell open.

Add Comment

Image 1/1: Insert the flat tool at a slight angle toward the left of the power cord. Depress the tab and pull the two halves of the shell apart.
  • Locate the second tab on the back of the device approximately 2 inches above the power cord.

  • Insert the flat tool at a slight angle toward the left of the power cord. Depress the tab and pull the two halves of the shell apart.

Add Comment

Image 1/1: Depress the tab using a flat tool at a slight angle and pull the halves apart.
  • Locate the bottom tab on the front side at the same height as the bottom tab on the back side.

  • Depress the tab using a flat tool at a slight angle and pull the halves apart.

Add Comment

Image 1/1: Depress the tab using the flat tool at a slight angle and finish pulling the removable half of the shell off.
  • Locate the last tab about one inch below the top on the front side.

  • Depress the tab using the flat tool at a slight angle and finish pulling the removable half of the shell off.

Add Comment

Image 1/1:
  • Locate the screw housing opposite of the control board, and remove the screw.

Add Comment

Image 1/1:
  • Locate the control board and grab it by the top and bottom firmly. Pull the board straight out being careful not to flex the circuit while removing.

Add Comment

Image 1/1:
  • Locate the screw that was being hidden by the control board and remove it to release the second half of the shell.

Add Comment

Image 1/1:
  • Remove the released half of the shell to finish removing the entire outer shell of the device.

Add Comment

Conclusion

To reassemble your device, follow these instructions in reverse order.

One other person completed this guide.

Nick Miller

Member since: 10/26/2016

101 Reputation

3 Guides authored

Team

IUPUI, Team 4-4, Baechle Fall 2016 Member of IUPUI, Team 4-4, Baechle Fall 2016

IUPUI-BAECHLE-F16S4G4

5 Members

7 Guides authored

0 Comments

Add Comment

View Statistics:

Past 24 Hours: 0

Past 7 Days: 0

Past 30 Days: 2

All Time: 27