  1. Bionaire BAP 600 Transformer Replacement, Control Board: step 1, image 1 of 1
    • Unplug 7 pin connector

  2. Bionaire BAP 600 Transformer Replacement: step 2, image 1 of 1
    • Unplug 2 pin wires which connects the front LED's.

  3. Bionaire BAP 600 Transformer Replacement: step 3, image 1 of 2 Bionaire BAP 600 Transformer Replacement: step 3, image 2 of 2
    • Remove two screws

  4. Bionaire BAP 600 Transformer Replacement: step 4, image 1 of 1
    • Unplug pins

    • Use scissors to cut zip ties

  5. Bionaire BAP 600 Transformer Replacement: step 5, image 1 of 3 Bionaire BAP 600 Transformer Replacement: step 5, image 2 of 3 Bionaire BAP 600 Transformer Replacement: step 5, image 3 of 3
    • Unplug rest of pin connections

    • Remove Neutral and Hot wires

    • They are the two black wires

    • Pull them out

  6. Bionaire BAP 600 Transformer Replacement: step 6, image 1 of 3 Bionaire BAP 600 Transformer Replacement: step 6, image 2 of 3 Bionaire BAP 600 Transformer Replacement: step 6, image 3 of 3
    • Unscrew two screws

    • Inspect capacitor for any bulges ( if it has a bulge , it means it is need to be replaced)

    • Check for burnt solder in the back of circuit board

  7. Bionaire BAP 600 Transformer Replacement, Transformer: step 7, image 1 of 2 Bionaire BAP 600 Transformer Replacement, Transformer: step 7, image 2 of 2
    • Use screwdriver to remove screws

Conclusion

To reassemble your device, follow these instructions in reverse order.

Alexander Tarancon

Member since: 10/12/16

49 Reputation

2 Guides authored

Team

IUPUI, Team 4-4, Baechle Fall 2016 Member of IUPUI, Team 4-4, Baechle Fall 2016

IUPUI-BAECHLE-F16S4G4

5 Members

7 Guides authored

0 Comments

Add Comment

View Statistics:

Past 24 Hours: 0

Past 7 Days: 1

Past 30 Days: 3

All Time: 194