Halogen Exam Light III Model #’s - 48700, 48722, 48724, 48726, 48728
Halogen Exam Light III
Halogen Exam Light III with Fiberoptic Light Pipe Model #'s - 48700, 48722, 48724, 48726, 48728
Halogen Exam Light III with Fiberoptic Light Cable Model #'s - 48780, 48782, 48784, 48786, 48788
Halogen Exam Light III with Neonate Light Pipe
Model #'s - 48760, 48762, 48764, 48766, 48768
Halogen Exam Light III Light Box with Power Cord
Model #'s - 48740, 48742, 48744, 48746, 48748
INTRODUCTION
Thank you for purchasing the Welch Allyn Halogen Exam Light III. We believe that it is the highest quality product of its kind available in the world today. By following the simple guidelines found within this manual, you should be rewarded with years of dependable, trouble free performance. If you have any questions or concerns please feel free to contact our customer or technical service departments at (800) 535-6663 during normal business hours.
Welch Allyn remains committed to providing innovative, quality diagnostic products for healthcare professionals. Call us at (800) 535-6663 to request a full line product catalog or visit us at our Web Site, www.WelchAllyn.com.
SYMBOL DESCRIPTIONS
Attention: Consult user's manual for additional information.
Warning: Risk of fire. Replace fuses as marked.
Caution: High Temperatures
Caution: High Intensity Light
WARNINGS & CAUTIONS
WARNING: The user of this equipment should be thoroughly trained in the medical procedures appropriate to the utilization of this instrumentation. Furthermore, time should be taken to read and understand the instructions contained within this manual prior to use of this product. Instructions for other equipment used in conjunction with the Exam Light III (for example: suction machines, electrosurgical generators, etc.) should also be read and understood. Failure to understand the operating requirements for this product may result in injury to yourself, the patient and/or may damage the instrument.
CAUTION: Electric Shock Hazard - Remove power cord from electrical outlet and allow lamp to cool before replacing (Welch Allyn lamp # 04200).
DANGER: Risk of explosion if used in the presence of flammable anesthetics.
CAUTION: Federal Law restricts this device to sale by or on the order of a physician.
CAUTION: Illumination is intense - Do not stare at the light source in operation. May be harmful to eyes.
CAUTION: Use the examination light in its intended working range of 12 to 24 inches. Exposures at closer distances may be harmful to skin.
WARNING: Do not perform neonatal trans-illumination without the use of the #48210 neonatal trans-illuminator (with U.V. filter). Do not remove the focusing sleeve from the light pipe and use the light pipe for trans-illumination. Severe burns may result.
General practices to minimize risk of harm to the skin from optical radiation hazards include: minimizing illumination intensity at the tissue examination site, minimizing exposure times, and taking additional precautions when skin sensitivity has been altered through tissue trauma or the use of anesthesia.
General good practices to minimize risk of harm to the eyes from optical radiation hazards include: avoid looking at bright light sources and their reflections, and protect eyes where normal pupil sizes and aversion responses are not present.
There are no user serviceable/replaceable parts other than lamp and fuses. Please refer any other service to qualified and authorized service centers.
COMPONENTS
Standard
Light Box, Power Cord and Wall Mount
Model 48740 (Domestic) Model 48742 (Europe) Model 48744 (UK) Model 48746 (Australia) Model 48748 (Japan)
Fiberoptic Light Pipe (shown with focusing sleeve)
Model 48200 (Included only with Model #'s 48700, 48722, 48724, 48726, and 48728)
Fiberoptic Light Cable (shown with focusing sleeve)
Model 48220 (Included only with Model #'s 48780, 48782, 48784, 48786, and 48788)
Neonatal Transilluminator
Model 48210 (Included only with Model #'s 48760, 48762, 48764, 48766, and 48768)
Focusing Sleeve
Model 48605 (Included only with Model #'s 48700, 48722, 48724, 48726, 48728, 48780, 48782, 48784, 48786, and 48788)
Accessories
0
Fiberoptic Light Pipe (Shown with Focusing Sleeve) Model 48200
Fiberoptic Light Cable (Shown with Focusing Sleeve) Model 48220
Focusing Sleeve
Model 48605
Neonatal Transilluminator
Model 48210 The optional neonatal Light Pipe/ transilluminator is used to assist in the diagnosis of pneumothorax, to locate blood vessels, etc. This transilluminator incorporates a permanently attached ultraviolet filter that minimizes the transmission of ultraviolet light. The standard Fiberoptic Light Pipe or Fiberoptic Light Cable should NOT be used for transillumination of neonates.
Table Mount Bracket
Model 48859
Mobile Stand Model 48850
Disposable Sheaths Model 52640
Disposable Sheath Dispenser Model 52641
35W Halogen Replacement Lamp Model 04200
MOUNTING
Use one of the following three mounting options in order to ensure proper operation of the light box.
Wall Mount
Choose appropriate mounting location. The length of the light pipe is 4 feet totally extended (fiberoptic light cable is 7.5 feet). When choosing a mounting location, keep these dimensions in mind in addition to accounting for the actual application the light will be used for and what portion of the examination table will need to be accessed.
-
Using the mounting plate as a template, mark drilling holes as needed (depending on your wall type).
-
Dry Wall, Paneling, Plywood or Plaster (1/8 inch (.3 cm) to 5/8 inch (1.6 cm) thick) - drill four (4) 3/8 inch (1cm) holes, insert hollow metal wall anchor assembly.
Concrete Block - drill four (4) 3/16 inch
- (.5 cm) holes, insert plastic anchors. Use #8 x 1/2 inch screws to secure.
-
Metal Panel or Plywood walls greater than 5/8 inch (1.60 cm) thick drill four (4) 1/8 inch (.3 cm) holes. Use #8 x 1 inch screws to secure.
- Once holes are drilled, install the mounting plate with the appropriate screws. Completely tighten the screw so there is no gap between the screw head and the mounting plate.