Contents
| 1. | The Hoyer Calibre Patient Lift........................................................................... | 3 |
|---|---|---|
| 2. | Introduction: About Your Lift ............................................................................. | 4 |
| 3. | Assembly and Commissioning Instructions ...................................................... | 5 |
| 4. | Safety Precautions............................................................................................ | 10 |
| 5. | Standard Control Box & Handset...................................................................... | 12 |
| 6. | Smart Monitor & Handset.................................................................................. | 13 |
| 7. | Operating Instructions ....................................................................................... | 17 |
| 8. | Removal of 6-point Cradle System................................................................... | 19 |
| 9. | Charging Instructions ........................................................................................ | 21 |
| 10. | Maintenance Schedule & Daily Check List ....................................................... | 22 |
| 11. | Technical Specifications.................................................................................... | 24 |
| 12. | Warranty............................................................................................................ | 27 |
Table Caption: This table is a table of contents for a manual for the Hoyer Calibre Patient Lift, outlining its sections and corresponding page numbers.
1. The Hoyer Calibre Patient Lift
2. Introduction: About Your Lift
Each Calibre lift is fully load tested and certified before being packed/shipped.
The packing consists of a strong, purpose built carton that is used for both export and domestic markets to ensure the safe arrival of the lift. A number of documents are supplied in a wallet, and packed with each lift and should be kept safely for future reference.
- TEST CERTIFICATE
- USER MANUAL
The TEST CERTIFICATE is an important document and will be required for your insurance records. It is valid for six months and after it has expired the lift should be inspected and serviced per the maintenance schedule.
To properly maintain your lift please refer to the maintenance schedule included in this document. If you are at all unsure what your country's servicing requirements are, please check with your dealer and/or a local government agency.
Statement of Intended Use
The Hoyer Calibre lift is a passive patient handling device intended for the safe lifting and transferring of patients up to a safe working load of 385 kg (850 lbs).
The Hoyer Calibre lift is intended for INDOOR USE ONLY and must be operated by a MINIMUM of two people/carers.
The Hoyer Calibre is an electrically operated patient lift, designed to support and promote safe patient handling and transfer for both the patient and carer.
The Hoyer Calibre is suitable for patients in the SITTING, SITTING/RECUMBENT and RECUMBENT positions. The slings suitable for use with this device are listed as follows:
- Hoyer Bariatric Hammock Sling (Safe working load - 385kg / 850lbs)
Expected Service Life
Hoyer Professional lifts are designed and tested for a minimum service life of ten (10) years, subject to the use and maintenance procedures stated in this manual. Use, other than in accordance with these instructions, may compromise service life.
3. Assembly and Commissioning Instructions
Carton Contents
Place the carton in a clear working area and open carefully. The carton contains:
- HOYER CALIBRE LIFT
- WALLET CONTAINING DOCUMENTS
- HAND CONTROL
- CHARGING LEAD
- BATTERY PACK
- DESK TOP CHARGER/STAND
Tools required
The following tools will be required for assembly:
- 13MM SOCKET
- TORqUE WRENCH
Warning
assembly and commissioning must be carried out by a competent engineer from an authorised Hoyer Service agent/Dealer.
Warning
a minimum of 2 perSonS requireD. The Hoyer Calibre is heavy and will need to be lifted with care. You will need assistance to lift the Hoyer Calibre from the carton.
Assembly Instructions
Remove all the parts from the carton and place on the floor, taking care to protect the paint finish from damage.
-
Place the mast/base assembly in a clear space and lay with rear castors and push handle on floor.
-
Fit the left and right hand legs (check correct orientation) onto the chassis using two M10 screws per leg as provided.
-
Tighten the M10 screws to secure each leg using a socket and torque wrench.
Warning
ensure the screws are secured firmly. it is recommended to tighten these to 10nm
Warning
avoid trapping fingers. Keep fingers away from the end of the leg when inserting into the leg socket. Keep fingers away from the front castor bracket during assembly of the legs to the base.
- Lift the Calibre onto its castors.
noTe: On a flat surface, all 6 castors must be in contact with the floor.
Warning
The Calibre is extremely heavy, a minimum of 2 people will be required to lift the hoist.
-
Insert the two bushings into the outside of the mounting brackets on either side of the boom. Lift the boom and position the actuator so that the upper fixing hole align with the mounting bracket holes on the boom.
-
Insert quick-release pin sleeve into mounting bracket/actuator hole. make sure the sleeve is fully engaged in the hole on both mounting brackets.
-
Insert the quick-release pin through the quick-release pin sleeve until it is fully located.
Warning
Check that the quick-release pin has been fully inserted by trying to push the pin back out.
- Fit power pack to the lift and make sure the latch holding the pack in place is fully engaged.
- 'Click' in place. Check that