Skip to main content

A collection of guides and support to help with washer repair.

3474 Questions View all

LG TrommWM2487HWM will not drain after changing pump and control board

I got OE code. I changed the drain assembly (including both drain & circulation pumps). I removed and cleaned the tub to pump and pump to drain hoses, there were no clogs. Still would not drain. I had pumps checked at local electric motor shop, they are good.

I changed the control board and the machine still will not drain. It passes test 11 & 12 of the QC Test Mode. It seems to fail test 2 & 3 - the machine does tumble. Everything works fine until it is time to drain. What else could it be?

Answer this question I have this problem too

Is this a good question?

Score 0
Add a comment

1 Answer

Most Helpful Answer

hi @cs108 ,

Since it fails QC 2 & 3 perhaps the sensor is faulty. (see heating without water section)

I think that this may be the sensor as it says heater, water level, frequency, thermistor, but I’m not sure.

Looking at the p.15 Program chart, the drain function comes just before the spin and the QC tests that fail are the spin tests.

Just what I would look at.

Was this answer helpful?

Score 1
Add a comment

Add your answer

Cheryl will be eternally grateful.
View Statistics:

Past 24 Hours: 0

Past 7 Days: 0

Past 30 Days: 1

All Time: 46