Skip to main content

Early 2011 Model: A1278 / 2.3 GHz i5 or 2.7 GHz i7 processor

782 Questions View all

Display blinks & no output after LCD replacement

Just replaced the LCD screen & glass on this A1278 MB Pro Unibody. When I start it up, the screen blinks, but immediately appears to shut down. I also replaced the HDD.

I can hear the SuperDrive running, as well as the fans, and it sounds a lot like it's trying to install the OS. I have no luck with the hardware diagnostic displaying either.

Any ideas?

Answered! View the answer I have this problem too

Is this a good question?

Score 1
1 Comment

Thats great Jim. Now if you would please change your comment to a answer and accept it to clear and archive it. +

by

Add a comment

1 Answer

Chosen Solution

Never mind, I went back in & re-seated the video cable at the logic board, and that fixed it.

Lesson: DOUBLE-CHECK YOUR CABLES!!

Was this answer helpful?

Score 1
Add a comment

Add your answer

Jim Peterson will be eternally grateful.