Hi everybody!!!

I had charging breakdown on my iPhone 5C. I decided to change the U2 chip because it was said that regularly faulty. I ordered few to the Chinese, desolder the old one with hot air under a x10 magnifying microscope than resolder a new one. It looks nice Under the micro.... but it does not work.

I removed accidently two close very small capacitors named C501 on the schematics. The phone is not recognized by iTunes and the voltage on the battery connector is unstable: 4,36V then 2,... then 1,5.. I tried to resolder the very tiny capacitors but it is very uneasy and I doubt that they are the cause of the malfunction......

Any advice or remark is welcome......... Thanks

Update

Block Image

Block Image

Here are the microscopic view of the U2 changed

Answer this question I have this problem too

Is this a good question?

Score 0

1 Comment:

What were the initial symptoms?

by

Add a comment

1 Answer

The 5C IPhone did charge at all. It booted only with a charged battery but was dead with a drained battery........ Thanks

Was this answer helpful?

Score 0
Add a comment