Skip to main content
Help

Current version by: L Pfaff ,

Text:

@gtocat99 , Arnold , Ensure receptacle is not working intermittently. Very carefully remove the circuit board and with magnifying glass, check for cracked solder joints and loose components/terminals/etc., as a board flexes/heats/cools cracked joints or loose components can connect and unconnect(open/close). Good luck. I hope this helped you out, if so let me know by pressing the helpful button.
@gtocat99 , Arnold , Ensure receptacle is not working intermittently. Very carefully remove the circuit board and with magnifying glass, check for cracked solder joints and loose components/terminals/etc., as a board flexes/heats/cools cracked joints or loose components can connect and unconnect(open/close). Good luck. I hope this helped you out, if so let me know by pressing the helpful button.

Status:

open

Original post by: L Pfaff ,

Text:

@gtocat99 , Arnold , Very carefully remove the circuit board and with magnifying glass, check for cracked solder joints and loose components/terminals/etc., as a board flexes/heats/cools cracked joints or loose components can connect and unconnect(open/close).   Good luck. I hope this helped you out, if so let me know by pressing the helpful button.

Status:

open